Development of a real-time monitoring photothermoplastic holographic recording instrument

  • Received Date: 1995-01-18
    Accepted Date: 1995-12-12
  • Based on the principles of real-time monitoring photothermoplastic holography, a practical photothermoplastic holographic recording instrument has been built up by using residual-heat andslow-heating method.The system consists of a DC high voltage power source and a AC low voltage Power source for charging sensitization and ohmic heating of the photothermoplastic plate,a corona-chargedevice, a copper grid and a transparent conductive plate. Especially,the corona-charge device has thefeatures of compact,transparent, uniform of charging density and easy to operate.The instrument cantake the high quality holograms for high diffraction efficient and high SNR of the system.This paper introduces the operation principle, structure and performances of the instrument.
  • 加载中
  • [1]

    Colbum W S, Tompkins E N. Appl ppt 1974;(13):2934
    [2]

    Kiilat U, Terrell D R. The Journal of Photographic Science. 1978;(26):183
    [3]

    Ineichen B, Liegeois C, Meyrueis P. Appl Opt 1982:(21):2209
    [4]

    Kryukov V V. Sov J Opt Tech 1991:58(3);131-133
    [5]

    Akacv A A, Kutanov A A. Abdrisaev B D et al.Soviet J Q E, 1992:22(8);730-734
    [6]

    Kutanov A A. Abdrisaev B D. Opt Spctrosc 1991;71(5):495-497
    [7] 史密斯HM,全息记录材料.北京:科学出版社.1984:218

    [8] 罗振坤,许澎翔.谢忠明et al应用激光.1995;15(4):163-166,148

    [9] 罗振坤,许澎翔,谢忠明et al激光技术,1994;18(1):46-49

    [10] 罗振坤.许澎翔.谢忠明et al影像技术.1995:(1):7-11

  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3223) PDF downloads(340) Cited by()

Proportional views

Development of a real-time monitoring photothermoplastic holographic recording instrument

  • 1. Institute of Radiation Medicine, Academy of Military Medical Sciences

Abstract: Based on the principles of real-time monitoring photothermoplastic holography, a practical photothermoplastic holographic recording instrument has been built up by using residual-heat andslow-heating method.The system consists of a DC high voltage power source and a AC low voltage Power source for charging sensitization and ohmic heating of the photothermoplastic plate,a corona-chargedevice, a copper grid and a transparent conductive plate. Especially,the corona-charge device has thefeatures of compact,transparent, uniform of charging density and easy to operate.The instrument cantake the high quality holograms for high diffraction efficient and high SNR of the system.This paper introduces the operation principle, structure and performances of the instrument.

Reference (10)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return