The noise and diffraction efficiency of display hologram

  • Received Date: 2000-03-22
    Accepted Date: 2000-05-29
  • The origins of various holographic noises and methods for restricting noises are discussed in the paper.While making hologram,the contrast of interference fringes is supposed to be increased in order to increase the diffraction.In order to obtain optimum diffraction efficiency and whole result,the ration of reference light and object light is chosen different with objects.In consideration of external environment,the exposure time should not be too long.In a certain condition,there is an optimum exposure time.Under the observation of electronic micrograph,it is shown that the information of interference fringes will be destroyed if the resolution of the recording materials is not high enough.Finally,some related problems are discussed.
  • 加载中
  • [1] 弗朗松 M.光学像的形成和处理.北京:科学出版社.1979:32~33

    [2] 弗朗松 M.衍射光学中的相干性.北京:科学出版社.1974:42~43

    [3] 张文碧,杨齐民,钟丽云 et al.激光杂志,1995:16(4):151

    [4] 杨齐民,张文碧,钟丽云.内蒙古工业大学学报,1998:17(4):63~66

    [5] 史密斯 H M.全息记录材料.北京:科学出版社,1984:27

    [6] 于美文.光学全息及信息处理.北京:国防工业出版社.1988:100

    [7] 张文碧,钟丽云,宫爱玲.激光杂志,1997:18(2):32~38

    [8] 杨齐民,钟丽云,张文碧.激光杂志,1999:20(3):36

    [9] 张文碧,杨齐民,钟丽云.激光杂志,1999:20(4):17

  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3341) PDF downloads(358) Cited by()

Proportional views

The noise and diffraction efficiency of display hologram

  • 1. Institute of Laser, Kunming University of Science and Technology, Kunming, 650051

Abstract: The origins of various holographic noises and methods for restricting noises are discussed in the paper.While making hologram,the contrast of interference fringes is supposed to be increased in order to increase the diffraction.In order to obtain optimum diffraction efficiency and whole result,the ration of reference light and object light is chosen different with objects.In consideration of external environment,the exposure time should not be too long.In a certain condition,there is an optimum exposure time.Under the observation of electronic micrograph,it is shown that the information of interference fringes will be destroyed if the resolution of the recording materials is not high enough.Finally,some related problems are discussed.

Reference (9)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return