Advanced Search
WANG Cong, JIN Jie, SHEN Lili. Measurement and research of optical characteristics of auto-stereoscopic display[J]. LASER TECHNOLOGY, 2016, 40(3): 367-371. DOI: 10.7510/jgjs.issn.1001-3806.2016.03.014
Citation: WANG Cong, JIN Jie, SHEN Lili. Measurement and research of optical characteristics of auto-stereoscopic display[J]. LASER TECHNOLOGY, 2016, 40(3): 367-371. DOI: 10.7510/jgjs.issn.1001-3806.2016.03.014

Measurement and research of optical characteristics of auto-stereoscopic display

More Information
  • Received Date: March 09, 2015
  • Revised Date: April 09, 2015
  • Published Date: May 24, 2016
  • In order to evaluate optical characteristics of auto-stereoscopic display, taking 8 viewpoint parallax barrier auto-stereoscopic display as an example, optical characteristics of auto-stereoscopic display of different viewpoint images were studied and the values of brightness and chromaticity at different visual angles were measured. Optical characteristics included optimal viewing position, crosstalk, viewing range, brightness uniformity, chromaticity uniformity and Moir fringes. The obtained data samples were analyzed. The results show that the method of measurement and analysis can evaluate the optical characteristics of multi-viewpoint stereoscopic display quantitatively and enhance the objectivity about the performance assessment of stereoscopic display. The study has an instructive effect on auto-stereoscopic display design.
  • [1]
    WANG P, ZHANG Y P, ZHANG J Q, et al. 3-D computer generated hologram display based on digital micro-mirror device[J].Laser Technology,2013,37(4):483-486(in Chinese).
    [2]
    WANG Q H, TAO Y H, LI D H, et al. 3-D auto-stereoscopic liquid crystal display based on lenticular lens[J]. Chinese Journal of Electron Devices, 2008, 31(1):296-298(in Chinese).
    [3]
    WANG Q H.3-D display technology and devices[M].Beijing:Science Press,2011:68-70(in Chinese).
    [4]
    LI X F, WANG Q H, LI D H, et al. Visual fatigue caused by auto-stereoscopic displays[J].Chinese Journal of Liquid Crystals and Displays, 2008, 23(4):464-467(in Chinese).
    [5]
    WU D Y, FAN K F, BU S P, et al. Methods of measurement for eyes crosstalk of 3DTV[J]. Video Engineering, 2012, 36(6):87-89(in Chinese).
    [6]
    HUANG Y, LI X H, XIA Z P, et al. Measurement method research on the optical characteristics of auto-stereoscopic display[C]//China FPD Conference.Shenzhen:Chinese Physical Society,2012:542-546(in Chinese).
    [7]
    LEE J H, SONG J K. Individual variation in 3-D visual fatigue caused by stereoscopic images[J]. IEEE Transactions on Consumer Electronics, 2012, 58(2):500-504.
    [8]
    HOU C P, XU G, SHEN L L. Analysis of viewing zone and simulation of the crosstalk based on multi-view auto-stereoscopic display[J]. Acta Photonica Sinica, 2013, 42(1):219-223(in Chinese).
    [9]
    HOU C P, WANG X Y. Crosstalk ratio evaluation of auto-stereoscopic display based on the slanted parallax barrier[J]. Journal of Tianjin University, 2012, 45(8):663-668(in Chinese).
    [10]
    LI X F,WANG Q H,LI D H, et al. Image processing to eliminate crosstalk between neighboring view images in three-dimensional lenticular display[J]. Journal of Display Technology, 2011, 7(8):443-447.
    [11]
    WU D Y, CAO J D, FAN K F. Research on range of crosstalk influencing comfort of 3-D TV[J].Video Engineering, 2013, 37(22):94-96(in Chinese).
    [12]
    LIU W. Performance test and evaluation methods of stereoscopic display[D]. Nanjing:Southeast University,2008:17-29(in Chinese).
    [13]
    BOEV A,GTCHEV A,EGIAZARIAN K. Crosstalk measurement methodology for auto-stereoscopic screens[C]//3DTV Conference.New York,USA:IEEE,2007:1-4.
    [14]
    HOU C P, XU G, SHEN L L. Calculation and simulation of viewing zone based on parallax barrier auto-stereoscopic display[J].Journal of Tianjin University,2012,45(8):677-681(in Chinese).
    [15]
    WANG Q H, PAN D D, LI X F, et al. Relation between viewer's pupil diameter and visual fatigue in auto-stereoscopic display[J]. Acta Photonica Sinica, 2011, 40(3):350-353(in Chinese).
    [16]
    ZHU Y L, CHEN R G, XIE J, et al. Principle of Moir fringe in auto-stereoscopic display based on parallax barrier and lenticular lens[J]. Chinese Journal of Liquid Crystals and Displays, 2009, 24(6):911-915(in Chinese).
  • Related Articles

    [1]LI Qi'nan, LI Dongyan, YU Haiping, LUO Xiaojie, DING Zhuang, XIANG Wangui. Stability of LD end-pumped Z-cavity Nd∶GdVO4 laser[J]. LASER TECHNOLOGY, 2024, 48(3): 438-442. DOI: 10.7510/jgjs.issn.1001-3806.2024.03.021
    [2]FAN Yiming, WEI Yong, ZHANG Ge, LI Hongming, TAO Jiayou, ZHOU Yueping. Analysis of thermal stability based on V-type folded cavity[J]. LASER TECHNOLOGY, 2018, 42(2): 206-211. DOI: 10.7510/jgjs.issn.1001-3806.2018.02.013
    [3]GUO Haiping, WAN Chenhao, XU Chengwen, YAN Tuo, WANG Dongsheng. Study on dynamic mode stability of external cavity diode lasers[J]. LASER TECHNOLOGY, 2016, 40(5): 706-710. DOI: 10.7510/jgjs.issn.1001-3806.2016.05.018
    [4]TANG Rui, SHEN Xue-ju. 分划板失调对猫眼光学系统反射特性的影响[J]. LASER TECHNOLOGY, 2012, 36(2): 271-274. DOI: 10.3969/j.issn.1001-3806.2012.02.034
    [5]CAO Yun-jiu, LIU Ye, CHEN Guang-long, XU Hong-xia. 圆柱体腔振动稳定性研究[J]. LASER TECHNOLOGY, 2012, 36(2): 262-264. DOI: 10.3969/j.issn.1001-3806.2012.02.031
    [6]YAN Ting-guang, LI Yu-de, XIAO Feng-xia, LIU Xian-kui, GAO Ke, FENG Tao. Near-field analysis of misaligned CO2 laser of two-dimension axisymmetric-fold combination cavity[J]. LASER TECHNOLOGY, 2008, 32(4): 402-405,444.
    [7]YANG Jia-gui. Temperature stability design for a laser diode module[J]. LASER TECHNOLOGY, 2007, 31(4): 445-448.
    [8]XIE Hui-ming, CHEN Hao-wei, JIA Sen, LI Li-sha, LI Long, ZHAO Yun-qing, BAI Jin-tao, HOU Xun. Double-end-pumped double Nd:YVO4 crystals continuous green laser[J]. LASER TECHNOLOGY, 2006, 30(6): 597-600.
    [9]Wang Peng-fei, . The influence of folded-resonator parameters on the stability ofintracavity-frequency-doubled lasers[J]. LASER TECHNOLOGY, 2003, 27(4): 328-330.
    [10]Wang Pengfei, . Study on noise suppression in intracavity-frequency-doubled lasers with folded resonator[J]. LASER TECHNOLOGY, 2003, 27(3): 172-174.

Catalog

    Article views PDF downloads Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return