Advanced Search

ISSN1001-3806 CN51-1125/TN Map

Volume 32 Issue 4
Apr.  2010
Article Contents
Turn off MathJax

Citation:

Near-field analysis of misaligned CO2 laser of two-dimension axisymmetric-fold combination cavity

  • Corresponding author: LI Yu-de, liyude15@yahoo.com.cn
  • Received Date: 2007-05-08
    Accepted Date: 2007-10-22
  • Under the condition of small angle misalignment,the effecton output beam's near-field distribution of CO2 lasers with two-dimensional axisymmetric-fold combination cavity was ascertained after analyzing and simulating beams combination output based on the axis determination of misaligned plano-concave and concave-plano-concave cavity resonator.The results showed that at small angle misalignment,the effect on near-field within 4cm was un-conspicuous and the light intensity was still at Gaussian distribution,and that out of the 4cm area,the effect became obvious with the misalignment angle.These results showed that the effect on near-field with 4cm was more practically.
  • 加载中
  • [1]

    XU Q Y,WANG X B.Continuous-wave high power CO2 lasers[M].Beijing:National Defense Industry Press,2000:48-122(in Chinese).
    [2]

    DIETMAR C,VWE H,HEINE-DIETER P.High-power CO2 laser with coaxial waveguide and diffusion cooling[J].IEEE J Q E,1993,29(7):2211-2219.
    [3]

    DIETMAR C,VWE H,HEINE-DIETER P.Ring resonator for laserswith annular gain media[J].Appl Opt,1994,33(30):6919-6924.
    [4]

    DIETMAR C,VWE H,HEINE-DIETER P,et al.Azimuthally unstable resonators for high-power CO2 laser with annular gain media[J].IEEE J Q E,1994,30(6):1440-1447.
    [5]

    ANTONIO L,MARCO C.Extraction of high-quality beams from narrow annular laser sources[J].Appl Opt,1999,38(21):4552-4557.
    [6]

    COLLEY A D,BAKER H J,HALL D R.Planar waveguide 1kW CW carbon dioxide laser excited by a single transverse RF discharge[J].A P L,1993,61(2):136.
    [7]

    WU G L,WANG Y Q,AN Ch W.The analysis of resonators for RF excited diffusion-cooled CO2 planar laser[J].Laser Technology,1998,22(2):121-123(in Chinese).
    [8]

    ZHANG Y Ch.Chinese laser industry last ten years[J].Laser & Infrared,2000,30(3):136-140(in Chinese).
    [9]

    YELDON E F,SEGUIN H J J,CAPIACK C E,et al.Multichannel slab discharge for CO2 laser excitation[J].A P L,1991,85(7):693-695.
    [10]

    YELDEN E F,SCOTT S W,STROHSCHEIN J D,et al.Symmetry enhancement and spot-size reduction through radial beam stacking in a multichannel CO2 laser array[J].IEEE J Q E,1994,30(8):1868-1875.
    [11]

    SEGUIN H J J.Power scaling of diffusion-cooled lasers[J].Opt & Laser Technol,1998,30(9):331-336.
    [12]

    LI Y D,LIU J L,CHEN M,et al.Axisymmetric-fold combination laser resonator[J].Opt Engng,2005,44(6):064204.
    [13]

    LIU J L,LI Y D,GUO J P,et al.Research on near-field distributions of axisymmetric folded-combined CO2 laser[J].Opt Engng,2006,45(7):074201.
    [14]

    LU B D.Laser optics[M].Chengdu:Sichuan University Press,1992:60-65,68-171,335-360(in Chinese).
    [15]

    LU Y X.Variation of misalignment sensitivity of a three-mirror cavity[J].Laser Technology,1991,15(3):154-157(in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(4501) PDF downloads(311) Cited by()

Proportional views

Near-field analysis of misaligned CO2 laser of two-dimension axisymmetric-fold combination cavity

    Corresponding author: LI Yu-de, liyude15@yahoo.com.cn
  • 1. School of Electronic and Information Science, Sichuan University, Chengdu 610064, China

Abstract: Under the condition of small angle misalignment,the effecton output beam's near-field distribution of CO2 lasers with two-dimensional axisymmetric-fold combination cavity was ascertained after analyzing and simulating beams combination output based on the axis determination of misaligned plano-concave and concave-plano-concave cavity resonator.The results showed that at small angle misalignment,the effect on near-field within 4cm was un-conspicuous and the light intensity was still at Gaussian distribution,and that out of the 4cm area,the effect became obvious with the misalignment angle.These results showed that the effect on near-field with 4cm was more practically.