Study on the gain of forward pumped Raman fiber amplifier by numerical simulation
-
1.
College of Photoelectric Information, University of Electronic Science and Technology of China, Chengdu 610054, China
-
Received Date:
2003-10-11
Accepted Date:
2003-11-26
-
Abstract
The relation between on-off gain of forward pumped Raman fiber amplifier and several important parameters,including Raman gain coefficient,pump power,fiber length,fiberloss,efficient area,etc.,is investigated by numerical simulation.The results are compared with the analytic solution under small signal.At last,several methods improving the on-off gain of Raman fiber amplifier are presented.
-
-
References
[1]
|
WANG L L,WANG B C,YANG L M.Gain transients in co-pumped and counter-pumped Raman amplifiers [J].Photon Technol Lett,2003,15(5):664~666. |
[2]
|
BONONI A,PAPARARO M.Transient gain dynamics in saturatedcounter-pumped Raman amplifiers [A].IEEE LEOS OSA OFC2002 Technical Digest [C].California:IEEE Communications Society,2002.511~512. |
[3]
|
KOCH F,CHERNIKOV S V,LEWIS S A E et al.Characterisation of single stage,dual-pumped Raman fibre amplifiers for different gain fibre lengths [J]. Electron Lett,2000,36(4):347~348. |
[4]
|
DIANOV E M,ABRAMOV A A,BUBNOV M M et al.30dB gain Raman amplifier at 1.3μm in low loss high GeO2-doped silica fibres [J].Electron Lett,1999,31(13):1057~1058. |
[5]
|
LEWIS S A E,CHERNIKOV S V,TAYLOR J R. Gain saturation in silica-fibre Raman amplifier [J].Electron Lett,1999,35(11):923~924. |
[6]
|
AGRAWAL G P. 非线性光纤光学 [M].天津:天津大学出版社,1992.241~242.
|
[7]
|
邓建中,刘之行.计算方法 [M].2版,西安:西安交通大学出版社,2001.224~230.
|
-
-
Proportional views
-