Advanced Search

ISSN1001-3806 CN51-1125/TN Map

Volume 36 Issue 3
Mar.  2012
Article Contents
Turn off MathJax

Citation:

Simulation of transverse position distributions of Cr atomic beam pre—collimated by three apertures

  • In order to study the effect of isotopes except for 52Cr on the transverse position distribution of Cr atomic beam,simulation was carried out for 1-D transverse laser cooling with a three-aperture pre-collimating slit by means of Monte Carlo method.The results show that isotopes except for 52Cr can make the background increased and affect characteristics of each part of the atomic beam: the central maximum value decreases 9.5% and its full width at half maximum(FWHM)increases 2.9% in the center;while the maximum value increases 25% with little increase of the FWHM in either side.It concludes that the existence of the isotopes except for 52Cr has little effect on the center maximum value and FWHM of the center part atomic beam.
  • 加载中
  • [1]

    CHU S.The manipulation of neutral particles[J].Reviews of ModernPhysics,1998,70 (3):685-706.
    [2]

    COHEN-TANNOUDJI C N.Manipulating atoms with photons[J].Reviews of Modern Physics,1998,70 (3):707-720.
    [3]

    PHILLIPS W D.Laser cooling and trapping of neutral atoms[J].Reviews of Modern Physics,1998,70(3):721-741.
    [4]

    TIMP G,BEIIRINGER R E,TENNANT D M,et al.Using light as a lens for submicron,neutral-atom lithography[J].Physical Review Letters,1992,69 (11):1636-1639.
    [5]

    McCIELLAND J J,SCHOLTEN RE,PALM C,et al.Laser-focused atomic deposition[J].Science,1993,262(5135):877-880.
    [6]

    LU X D,LI T B,MA Y.Broadening of Gr nanostructures in laser-focused atomic deposition[J]. Chinese Physics,2010,B19 (12):123201 / 1-123201/6.
    [7]

    ZHANG B W,MA Y,ZHAO M,et al.3-D simulation of nano-grating by Cr atom beam deposition[J].Laser Technology,2011,35(3):364-367 (in Chinese).
    [8]

    McCLELLAND J J,ANDERSON W R,BRADLEY C C,et al.Accuracy of nanoscale pithstandards fabribcated by laser-focused atomic deposition[J].Journal of Research of the National Institute of Standards and Technology,2003,108(2):99-113.
    [9]

    LI T B.Nanometrology and transfer btandard[J].Shanghai Measurement and Testing,2005,32 (1):8-13 (in Chinese).
    [10]

    ZHENG C L,LI T B,MA Y,et al.Analysis of Cr atom trajectory and focusing deposition in the standing wave field[J].Acta Physica Sinica,2006,55 (9):4528-4534 (in Chinese).
    [11]

    McCLELLAND J J.Atom-optical properties of a standing-wave light field[J].Journal of the Optical Society of America,1995,B12(10):1761-1767.
    [12]

    ZHANG B W,MA Y,LI T B.Collimation of chromium atomic beam by means of 1-D Doppler laser[J].Laser Technology,2009,33(4):347-350(in Chinese).
    [13]

    ZHANG B W,ZHANG W T,MA Y,et al.Collimation of chromium beam by one-dimensional Doppler laser with large collimating slit[J].Acts Physica Sinica,2008,57(9):5485-5490(in Chinese).
    [14]

    ZHANG B W,LI T B,MA Y.One-dimensional Doppler laser collimation of chromium beam with a novel pre-collimating scheme[J].Chinese Optics Letters,2008,6(10):782-784.
    [15]

    METCALF H J,STRATEN P.Laser cooling and trapping[M].Berlin:Springer-Verlag,1999:88.
    [16]

    CAI W Q,LI C W,HUO Y S,et al.Atom lithograph[J].Acta Physica Sinica,1999,48(4):611-619.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3931) PDF downloads(474) Cited by()

Proportional views

Simulation of transverse position distributions of Cr atomic beam pre—collimated by three apertures

    Corresponding author: ZHANG Bao-wu, zhangbaowu1978@gmail.com
  • 1. College of Metrology & Measurement Engineering, China Jiliang University, Hangzhou 310018, China;
  • 2. State Key Laboratory of Precision Measurement Technology and Instruments, Tsinghua University, Beijing 100084, China;
  • 3. Tongji University, Shanghai Key Laboratory of Special Artificial Microstructure Materials and Technology, Shanghai 200092, China

Abstract: In order to study the effect of isotopes except for 52Cr on the transverse position distribution of Cr atomic beam,simulation was carried out for 1-D transverse laser cooling with a three-aperture pre-collimating slit by means of Monte Carlo method.The results show that isotopes except for 52Cr can make the background increased and affect characteristics of each part of the atomic beam: the central maximum value decreases 9.5% and its full width at half maximum(FWHM)increases 2.9% in the center;while the maximum value increases 25% with little increase of the FWHM in either side.It concludes that the existence of the isotopes except for 52Cr has little effect on the center maximum value and FWHM of the center part atomic beam.

Reference (16)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return