Advanced Search
Chen Xiao, Xu Rongqing, Shen Zhonghua, Lu Jian, Ni Xiaowu. Reflected laser ultrasonic sensor for testing thickness and its application[J]. LASER TECHNOLOGY, 2003, 27(6): 557-559.
Citation: Chen Xiao, Xu Rongqing, Shen Zhonghua, Lu Jian, Ni Xiaowu. Reflected laser ultrasonic sensor for testing thickness and its application[J]. LASER TECHNOLOGY, 2003, 27(6): 557-559.

Reflected laser ultrasonic sensor for testing thickness and its application

More Information
  • Received Date: April 24, 2003
  • Revised Date: June 29, 2003
  • Published Date: November 24, 2003
  • A new laser ultrasonic sensor for testing samples' thickness is developed.The detection principle is discussed in detail.This sensor has high-frequency response,high sensitivity and is easy to adjust.The sensor is used to detect laser-induced ultrasonic longitude-wave at the epicenter of the rear metallic surface when pulse Nd:YAG laser is focused on polished iron plate.Well-defined longitude-wave and its echo waves are acquired.Based on the experimental results,the sample's thickness can be deduced.The theoretical and experimental results are in good agreement with relative error of 0.5%.
  • [1]
    应崇福.超声学.北京:科学出版社,1993:103~112.
    [2]
    袁易全.超声换能器.南京:南京大学出版社,1989:130~191.
    [3]
    金长善.超声工程.哈尔滨:哈尔滨工业大学出版社,1989:189~205.
    [4]
    袁易全,陈思忠.近代超声原理与应用.南京:南京大学出版社,1996:353~354.
    [5]
    Aussel J D,Brun A L,Baboux J C.Ultrasonics,1988,26:245~255.
    [6]
    陆建,侯锐,陈建平 et al.第八届现代声学国际会议.北京:科学出版社,2001,11(S312):103~105.

Catalog

    Article views (1) PDF downloads (4) Cited by()

    /