Citation: | LI Hui, CAO Yu, LIU Hongbo, PENG Dong, ZHU Yukun, WANG Kun, TIAN Jie. High-speed and 128-channel multi-spectral photoacoustic tomography system for small animal[J]. LASER TECHNOLOGY, 2017, 41(5): 669-674. DOI: 10.7510/jgjs.issn.1001-3806.2017.05.010 |
[1] |
KARABUTOV A, SAVATEEVA E, ORAEVSKY A. Optoacoustic tomography:New modality of laser di agnostic systems[J]. Laser Physics, 2003, 13(5):711-723.
|
[2] |
WANG L V, HU S. Photoacoustic tomography:in vivo imaging from organelles to organs[J]. Science, 2012, 335(6705):1458-1462. http://d.old.wanfangdata.com.cn/OAPaper/oai_pubmedcentral.nih.gov_3322413
|
[3] |
WANG X, PANG Y, KU G, et al. Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain[J]. Nature Biotechnology, 2003, 21(7):803-806. DOI: 10.1038/nbt839
|
[4] |
LI C, WANG L V. Photoacoustic tomography and sensing in biomedicine[J]. Physics in Medicine and Biology, 2009, 54(19):R59-R97. DOI: 10.1088/0031-9155/54/19/R01
|
[5] |
WANG L V. Prospects of photoacoustic tomography[J].Medical Physics, 2008, 35(12):5758-5767. DOI: 10.1118/1.3013698
|
[6] |
NTZIACHRISTOS V, RAZANSKY D. Molecular imaging by means of multispectral optoacoustic tomography (MSOT)[J]. Chemical Reviews, 2010, 110(5):2783-2794. DOI: 10.1021/cr9002566
|
[7] |
KOLKMAN R G M, BRANDS P J, STEENBERGEN W, et al. Real-time in vivo photoacoustic and ultrasound imaging[J]. Journal of Biomedical Optics, 2008, 13(5):050510. DOI: 10.1117/1.3005421
|
[8] |
NIEDERHAUSER J J, JAEGER M, LEMOR R, et al. Combined ultrasound and optoacoustic system for real-time high-contrast vascular imaging in vivo[J]. IEEE Transactions on Medical Imaging, 2005, 24(4):436-440. DOI: 10.1109/TMI.2004.843199
|
[9] |
OLAFSSON R, BAUER D R, MONTILLA L G, et al. Real-time, contrast enhanced photoacoustic imaging of cancer in a mouse window chamber[J]. Optics Express, 2010, 18(18):18625-18632. DOI: 10.1364/OE.18.018625
|
[10] |
XU D, LIANG Zh X, JI X. Photoacoustic imaging system based on multi-channel parallel acquisition[J]. Chinese Journal of Lasers, 2011, 38(2):0204002(in Chinese). DOI: 10.3788/CJL
|
[11] |
XIANG L, WANG B, JI L, et al. 4-D photoacoustic tomography[J]. Scientific Reports, 2013, 3:1113. DOI: 10.1038/srep01113
|
[12] |
TAN Y, HE J F, REN Y J, et al. Fast photoacoustic imaging systems based on rotating multi-element linear transducer array[J]. Laser Technology, 2009, 33(5):300-302(in Chinese). http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=jgjs200903032
|
[13] |
CHEN Z, TANG Z, WAN W. Photoacoustic tomography imaging based on a 4f acoustic lens imaging system[J]. Optics Express, 2007, 15(8):4966-4976. DOI: 10.1364/OE.15.004966
|
[14] |
KOZHUSHKO V, KHOKHLOVA T, ZHARINOV A, et al. Focused array transducer for two-dimensional optoacoustic tomography[J]. The Journal of the Acoustical Society of America, 2004, 116(3):1498-1506. DOI: 10.1121/1.1781710
|
[15] |
KRUGER R A, KISER W L, Jr, REINECKE D R, et al. Thermoacoustic computed tomography using a conventional linear transducer array[J]. Medical Physics, 2003, 30(5):856-860. DOI: 10.1118/1.1565340
|
[16] |
PARK S, MALLIDI S, KARPIOUK A B, et al. Photoacoustic imaging using array transducer[C]//International Society for Optics and Photonics. San Jose, USA: SPIE, 2007: 643714.
|
[17] |
YIN B, XING D, WANG Y, et al. Fast photoacoustic imaging system based on 320-element linear transducer array[J]. Physics in Medicine and Biology, 2004, 49(7):1339-1346. DOI: 10.1088/0031-9155/49/7/019
|
[18] |
ZEMP R J, BITTON R, LI M L, et al. Photoacoustic imaging of the microvasculature with a high-frequency ultrasound array transducer[J]. Journal of Biomedical Optics, 2007, 12(1):010501. DOI: 10.1117/1.2709850
|
[19] |
KRUGER R A, KISER W L, REINECKE D R, et al. Thermoacoustic molecular imaging of small animals[J]. Molecular Imaging, 2003, 2(2):113-123. DOI: 10.1162/153535003322331993
|
[20] |
GAMELIN J, AGUIRRE A, MAURUDIS A, et al. Curved array photoacoustic tomographic system for small animal imaging[J]. Journal of Biomedical Optics, 2008, 13(2):024007. DOI: 10.1117/1.2907157
|
[21] |
YANG S, XING D, ZHOU Q, et al. Functional imaging of cerebrovascular activities in small animals using high-resolution photoacoustic tomography[J]. Medical Physics, 2007, 34(8):3294-3301. DOI: 10.1118/1.2757088
|
[22] |
COX B T, KARA S, ARRIDGE S R, et al. k-space propagation models for acoustically heterogeneous media:Application to biomedical photoacoustics[J]. The Journal of the Acoustical Society of America, 2007, 121(6):3453-3464. DOI: 10.1121/1.2717409
|
[23] |
DEAN-Ben X L, BUEHLER A, NTZIACHRISTOS V, et al. Accurate model-based reconstruction algorithm for three-dimensional optoacoustic tomography[J]. IEEE Transactions on Medical Imaging, 2012, 31(10):1922-1928. DOI: 10.1109/TMI.2012.2208471
|
[24] |
DEAN-BEN X L, NTZIACHRISTOS V, RAZANSKY D. Acceleration of optoacoustic model-based reconstruction using angular image discretization[J]. IEEE Transactions on Medical Imaging, 2012, 31(5):1154-1162. DOI: 10.1109/TMI.2012.2187460
|
[25] |
LIU H, WANG K, PENG D, et al. Curve-driven-based acoustic inversion for photoacoustic tomography[J]. IEEE Transactions on Medical Imaging, 2016, 35(12):2546-2557. DOI: 10.1109/TMI.2016.2584120
|
[26] |
ZENG L, XING D, GU H, et al. High antinoise photoacoustic tomography based on a modified filtered backprojection algorithm with combination wavelet[J]. Medical Physics, 2007, 34(2):556-563. DOI: 10.1118/1.2426406
|
1. |
杨宇,杨发展,姜芙林,黄珂,刘朝伟. 激光加工微织构研究进展及其在改善摩擦学特性方面的功能分析. 工具技术. 2023(07): 3-12 .
![]() | |
2. |
邹云,桑振宽,李大磊,李阳. 304不锈钢水射流强化工艺的多目标优化设计. 表面技术. 2018(02): 25-29 .
![]() | |
3. |
张冲,王冠,杨志刚,刘赞丰. 脉冲光纤激光切割连杆裂解槽工艺参量优化. 激光技术. 2018(03): 422-426 .
![]() | |
4. |
符永宏,邹国文,黄婷,康正阳,李海波,郑峰. Cr12mov模具钢表面激光毛化工艺及力学性能研究. 应用激光. 2018(01): 76-80 .
![]() | |
5. |
凌步军,刘新金,倪振兴,潘文金,贾明明. 激光毛化表面微形貌成形工艺实验研究. 现代制造技术与装备. 2017(11): 30-33 .
![]() |