Ocular aberrations measurement method combined with subjective visual compensation

  • Corresponding author: CHEN Jia-bi, jbchenk@online.sh.cn
  • Received Date: 2009-10-19
    Accepted Date: 2010-12-31
  • In order to measure various low-level aberration and irregular higher-order aberration of the human eyes accurately,the wave-front aberration measurement method with subjective visual compensation was proposed,which could ensure more accurate and realistic measuring results.The result shows the wave-front aberration obtained from subjective visual compensation measuring method smaller than objective measurement,which is the result of adaptive correction.In addition, when watching different sighting targets,the fluctuation value of wave front aberration is small.Therefore,a conclusion can be drawn that the subjective visual compensation measuring method takes into consideration the actual condition of human eyes when watching targets,which contributes to aberration measuring improvement and obtains results that match realistic state.The conclusion is positive and beneficial to the aberration treatment of human eyes.
  • 加载中
  • [1]

    NAVARRO R,ARTAL P,WILLIAMS D R,et al.Modulation transfer of the human eye as a function of retinal eccentricity[J].J O S A,1993,A10(2):201-212.
    [2]

    WILLIAMS D R,BRAINARD D H,McMAHON M J,et al.Double-pass and interferometric of the normal human eye[J].J O S A,1994,A11(12):3123-3135.
    [3]

    ARTAL P,MARCOS S,NAVARRO R,et al.Odd aberrations and double-pass measurements of retinal image quality[J].J O S A,1995,A12(2):195-201.
    [4]

    LÓPEZ-GIL N,ARTAL P.Comparison of double-pass estimates retinal-image quality obtained with green and near-infrared light[J].J O S A,1997,A14(5):961-971.
    [5]

    LIANG J,WESTHEIMER G.Optical performances of human eyes derived from double-pass measurements[J].J O S A,1995,A12(7):1411-1416.
    [6]

    MA J Sh,MA H,CHEN J B,et al.The development of measurements of aberrations of the human eye[J].Optical Instruments,2004,26(1):64-71(in Chinese).
    [7]

    CAO L,YANG X,ZHANG P M.Research on human eye aberration measurements[J].Optical Instruments,2008,30(4):87-92(in Chinese).
    [8]

    LIANG J,GRIMM B,GOELZ S,et al.Objective measurement of the wave aberrations of the human eye with the use of a Hartmann-Shack wave-front sensor[J].J O S A,1994,A11(7):1949-1957.
    [9]

    SMITH G,COX M J,CALVER R,et al.The spherical aberration of the crystalline lens of the human eye[J].Vision Research,2001,41(2):235-243.
    [10]

    SHENG Y,YANG Y B,FU Q.Comparison of the refraction results measured with MEL-70 wavefront analyzer and classical methods[J].Recent Advances in Ophthalmology,2005,25(1):54-56(in Chinese).
    [11]

    SHEN J X,YE H.Wavefront aberration guided excimer laser cornea ablation[J].Applied Laser,2004,24(2):102-106(in Chinese).
    [12]

    MARTINEZ A A,PANDIAN F A,SANKARIDURG P,et al.Comparison of aberrometer and autorefractor measures of refractive error in children[J].Ptometry and Vision Science,2006,83(11):E811-E817.
    [13]

    WADE N J.Image,eye and retina[J].J O S A,2007,A24(5):1229-1249.
    [14]

    HU L G,ZHOU R R,LIAO W H.Subjective measurement principle and implementation of ocular wave-front aberrations[J].Chinese Journal of Quantum Electronics,2005,22(4):626-632(in chinese).
    [15]

    KONG M M,GAO Zh Sh,CHEN L,et al.Research and development of the optical model of human eyes[J].Laser Technology,2008,32(4):370-373(in Chinese).
    [16]

    CAO Zh L,SHEN J X,LIAO W H.Research of excimer laser corneal surgery and flying-spot scanning algorithmp[J].Laser Technology,2006,30(6):631-635(in Chinese).
    [17]

    DENG G Q,YU Y Sh.Development and experimental study of excimer laser refractive system[J].Laser Technology,2005,29(4):417-419(in Chinese).
    [18]

    ZHANG P M.Study on the sujective and objective measurement for the ocular wavefront aberration[D].Shanghai:University of Shanghai for Science and Technology,2009:65-75(in Chinese).
    [19]

    HOWLAND H C,HOWLAND B.A subjective method for the measurement of monochromatic[J].J O S A,1977,67(11):1508-1518.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(5171) PDF downloads(228) Cited by()

Proportional views

Ocular aberrations measurement method combined with subjective visual compensation

    Corresponding author: CHEN Jia-bi, jbchenk@online.sh.cn
  • 1. Caboratory of Medical Optics & Optometry, School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China;
  • 2. School of Optical-Electrical Engineering, Changzhou Institute of Technology, Changzhou 213002, China;
  • 3. Shanghai Medical Instrumentation College, Shanghai 200093, China

Abstract: In order to measure various low-level aberration and irregular higher-order aberration of the human eyes accurately,the wave-front aberration measurement method with subjective visual compensation was proposed,which could ensure more accurate and realistic measuring results.The result shows the wave-front aberration obtained from subjective visual compensation measuring method smaller than objective measurement,which is the result of adaptive correction.In addition, when watching different sighting targets,the fluctuation value of wave front aberration is small.Therefore,a conclusion can be drawn that the subjective visual compensation measuring method takes into consideration the actual condition of human eyes when watching targets,which contributes to aberration measuring improvement and obtains results that match realistic state.The conclusion is positive and beneficial to the aberration treatment of human eyes.