Influence of cavity length change on measurement of CW cavity ring-down
-
1.
College of Optoelectric Science and Engineering, National University of Defence Technology, Changsha 410073, China
-
Corresponding author:
LONG Xing-wu, Xwlong110@sina.com
-
Received Date:
2006-06-29
Accepted Date:
2006-11-10
-
Abstract
In order to clarify the impact of cavity length change on measurement,taking the laser's line-width into account,the influence of cavity length change on the measurement of cavity ring-down in two limiting cases was analyzed and simulated by using cavity ring-down and multiple-beam interferometry theory,hereby the general cases were discussed.Analyses showed the instability chiefly changed resonant frequency of ring-down cavity,then varied the emergent light power and the feature of ring-down signal,which shouled bring serious measurement error.All of these will provide theory direction to measurement error analysis and improve measurement accuracy.
-
-
References
[1]
|
BERDEN G,PEETERS R,MEIJER G.Cavity ring-down spectroscopy:experimental schems and applications[J].International Reviews in Physical Chemistry,2000,19(4):565~607. |
[2]
|
O'KEEFE A,DEACON D A G.Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources[J].Review of Science Instrum,1988,59(12):2544~2551. |
[3]
|
SUN F G,DAI D X,XIE J Ch et al.Accurate reflectivity measurement of high reflective mirrors via a cavity ring-down method[J].Chinese Journal of Lasers,1999,A26(1):35~38(in Chinese). |
[4]
|
YI H Y,PENG Y,HU X Y et al.Influence of length misadjustment of ring-down cavity on its output power[J].Chinese Journal of Lasers,2003,31(S1):486~488(in Chinese). |
[5]
|
YI H Y,LÜ B D,HU X Y et al.Influence of length misadjustment on its metrical precision of ring-down cavity spectroscopy[J].High Power Laser and Partical Beams,2004,16(8):993~996(in Chinese). |
[6]
|
YI H Y,LÜ B D,PENG Y et al.Influence of detector's aperture on metrical precision of ring-down cavity[J].Laser Technology,2004,28(3):231~236(in Chinese). |
[7]
|
YI H Y,PENG Y,TIAN X Q et al.Experimental study of reflectivity measurement of single wavelength by cavity ring-down method[J].Laser Technology,2005,29(4):337~339(in Chinese). |
[8]
|
ANDERSON D Z,FRISCH J C,MASSER C S.Mirror reflectometerbased on optical cavity decay time[J].Appl Opt,1984,23(8):1238~1245. |
[9]
|
ZHOU B K,GAO Y Zh,CHEN Ch R et al.Theory of laser[M].Beijing:Defence Industry Press,2000.166~167(in Chinese). |
[10]
|
CHEN X Z,YAO J L,LI Y M et al.A narrow linewidth diode laser for high resolution spectroscopy and its properties[J].Acta Optical Sinica,1996,16(10):1383~1388(in Chinese). |
[11]
|
HE G Y.Usual numerical value arithmetic volume of visual C++[M].Beijing:Science Press,2002.466~517(in Chinese). |
[12]
|
PEI Sh X,GAO X M,CUI F P et al.Study of cavity enhanced absorption spectroscopy based on a swept diode laser[J].Optics & Optoelectronic Technology,2004,2(6):30~33(in Chinese). |
-
-
Proportional views
-