Experimental study of a kalium titanyl arsenate optical parametric oscillator in the mid-infrared band
-
WANG Bin1,2,
-
REN Gang1,3,
-
LI Tong1,
-
NIU Rui-hua1,
-
YU Shu-fan1,
-
ZHONG Ming1,
-
LÜ Bai-da2, ,
-
1.
Southwest Institute of Technical Physics, Chengdu 610041, China;
-
2.
Institute of Laser Physics and Chemistry, Sichuan University, Chengdu 610064, China;
-
3.
School of Electronics and Information Engineering, Sichuan University, Chengdu 610064, China
-
Corresponding author:
LÜ Bai-da, badalu@scu.edu.cn
-
Received Date:
2006-05-10
Accepted Date:
2006-07-22
-
Abstract
For the propose of finding high energy mid-infrared laser output,a compound cavity kalium titanyl arsenate(KTA) optical parametric oscillator(OPO) pumped by an electro-optic Q-switched flash-lamp-pumped 1064nm Nd:YAG laser was experimentally studied.Single pulse energy of 36mJ of the OPO was obtained at a repetition rate of 1Hz,where the idler pulse energy was 11mJ at 3407nm wavelength with pulse width of 10ns.The pulse energy decreased with increasing the repetition rate within the range of 5Hz~40Hz.The experimental result shows that the compound cavity pumping technology has the advantage of enhancing conversion efficiency and reducing oscillator threshold.With a mid-infrared image apparatus illuminated by the OPO,the laser spot was observed from the monitor of the image system.This result is useful for mid-infrared laser study.
-
-
References
[1]
|
REN G G,HUANG Y N.Laser-based IRCM system defenses for military and commercial aircraft[J].Laser Infrared,2006,23(1):1~6(in Chinese). |
[2]
|
YAO B Q,WANG Y Z,WANG Q.Development of mid-infrared optical parametric oscillator[J].Laser Technology,2002,26(3):217~220(in Chinese). |
[3]
|
WAN Y,LAN G,SU X Z et al.High energy output compound cavity pump optical parametric oscillator in the mid infrared[J].Laser Technology,2005,29(4):340~342(in Chinese). |
[4]
|
WANG K Q,PEI B.Mid-infrared parametric oscillator with 3.76μm output[J].Chinese Journal of Lasers,2000,27(8):691~693(in Chinese). |
[5]
|
WU R F,LAI K S,WONG H F et al.Multiwatt mid-IR output from a Nd:YALO laser pumped intracavity KTA OPO[J].Optics Express,2001,8(13):694~698(in Chinese). |
[6]
|
WEBB M S,MOULTON P F,KASINSKI J J et al.High-average-power KTiOAsO4 optical parametric oscillator[J].Opt Lett,1998,23(15):1161~1163. |
[7]
|
LAVI R,ENGLANDER A,LALLOUZ R.Highly efficient low-threshold tunable all-solid-state intracavity optical parametric oscillator in the mid infrared[J].Opt Lett,1996,21(11):800~802. |
[8]
|
RUFFING B,NEBEL A,WALLENSTEIN R.A 20W KTA-OPO synchronously pumped by a CW modelocked Nd:YVO4 oscillator-amplifier system[A].CLEO 97[C].Washington D C:CLEO,1997.199. |
[9]
|
MARSHALL L R.Efficient multiwatt 2μm~5μm tunable sources[A].CLEO 96[C].Washington D C:CLEO,1996.368~369. |
[10]
|
DEBUISSCHERT T,RAFFY J,POCHOLLE J P et al.Intracavity optical parametric oscillator:study of the dynamics in pulsed regime[J].J O S A,1996,B13(7):1569~1587. |
-
-
Proportional views
-