Femtosecond pulse compression in external cavity

  • Received Date: 2006-08-14
    Accepted Date: 2006-11-28
  • In order to get shorter pulse width to improve time resolution,femtosecond pulse was compressed by using two prisms and a reflective mirror.Femtosecond pulse was measured with a home-made second-harmonic generation frequency-resolved optical gating.The temporal width of input pulse was 89fs,the time-bandwidth product was 0.9096,the minimum error was 2.4‰ and the average power of the input light was about 480mW.The width of compressed pulse was 22fs,the time-bandwidth product was 0.44203,the minimum error was 1.1‰ and the average power of the output light was about 250mW.The compression ratio was 4:1,which was higher than that in the related report.The experimental results indicate that the compressing device is valid and the result is useful for getting shorter pulses.
  • 加载中
  • [1]

    FEURER T,VAUGHAN J C,NELSON K A.Spatiotemporal coherent control of lattice vibrational wave[J].Science,2003,299(5605):374~377.
    [2]

    RABITZ H.Shaped laser pulse as reagents[J].Science,2003,299(5606):525~527.
    [3]

    TIAN P,KEUSTERS D,SUZAKI Y et al.Femtosecond phase-coherent two-dimensional spectroscopy[J].Science,2003,300(5625):1553~1555.
    [4]

    CHEN B F.Numerical simulation of femtosecond pulses measurement with SPIDER[J].Laser Technology,2006,30(1):13~15(in Chinese).
    [5]

    YU Y L,MU C J,BAI J T et al.The design of a new multilayer blazed reflective grating used in broadening femtosecond lasers[J].Laser Technology,2005,29(4):358~360(in Chinese).
    [6]

    YOU M,ZHAO W,CHEN G H et al.Crystallization in PTR glass induced by irradiation of femtosecond lasers[J].Laser Technology,2006,30(1):40~42(in Chinese).
    [7]

    ZHAO G,CHEN J G,ZHANG Q et al.Analytical description of the damage threshold of femtosecond pulses[J].Laser Technology,2006,30(1):90~92(in Chinese).
    [8]

    FORK R L,BRITO C C H,BECKER P C et al.Compression of optical pulses to six femtoseconds by using cubic phase compensation[J].Opt Lett,1987,12(7):483~485.
    [9]

    HACKER M,STOBRAWA G,SAUERBREY R.Femtosecond-pulsesequence compression by Gires-Tournois interferometers[J].Opt Lett,2003,28(3):209~211.
    [10]

    SCHEHRER K L,FORK R L,AVRAMOPOULOS H et al.Derivation and measurement of the reversible temporal lengthening of femtosecond optical pulses for the case of a four-prism sequence[J].Opt Lett,1990,15(10):550~552.
    [11]

    FORK R L,BRITO C C H,BECKER P C et al.Compression of optical pulses to six femtosecond by using cubic phase compensation[J].Opt Lett,1987,12(7):483~485.
    [12]

    COJOCARU E.Analytic Expressions for the fourth and the fifth-order dispersions of crossed prisms pairs[J].Appl Opt,2003,42(34):6910~6914.
    [13]

    FORK R L,MARTINEZ O E.Negative dispersion using pairs of prisms[J].Opt Lett,1984,9(5):150~152.
    [14]

    TREBINO R.Frequency-resolved optical gating:The measurement ofUltrashort Laser Pulse[M].Boston:Kluwer Academic Publishers,2002.101~322.
    [15]

    WURZER A J,LOCHBRUNNER S,RIEDLE E.Highly localized vibronic wavepackets in large reactive molecules[J].Appl Phys,2000,71(3)405~409.
    [16]

    BAUM P,LOCHBRUNNER S,GALLMANN L et al.Real-time char-acterization and optimal phase control of tunable visible pulses with a flexible compressor[J].Appl Phys,2002,B74(S)219~224.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(4780) PDF downloads(537) Cited by()

Proportional views

Femtosecond pulse compression in external cavity

  • 1. Department of Optics and Electronics Sciences, Harbin Institute of Technology at Weihai, Weihai 264209, China

Abstract: In order to get shorter pulse width to improve time resolution,femtosecond pulse was compressed by using two prisms and a reflective mirror.Femtosecond pulse was measured with a home-made second-harmonic generation frequency-resolved optical gating.The temporal width of input pulse was 89fs,the time-bandwidth product was 0.9096,the minimum error was 2.4‰ and the average power of the input light was about 480mW.The width of compressed pulse was 22fs,the time-bandwidth product was 0.44203,the minimum error was 1.1‰ and the average power of the output light was about 250mW.The compression ratio was 4:1,which was higher than that in the related report.The experimental results indicate that the compressing device is valid and the result is useful for getting shorter pulses.

Reference (16)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return