The study of signal transmission characteristic in airborne particle counter

  • In order to study the essential characteristic of airborne particle counter signal transmission,some basic characteristics of airborne particle counter are studied with proceeding from single particle signal,including collecting characteristic of scattered light and photoelectric transfer characteristic.Based on these,statistics characteristic of signal distribute of single particle group and signal transmission characteristic of mixed particles group were analyzed.At the same time,the experiment was performed and the result is consistent with the theory with the correlation coefficient more than 0.9.Results indicate the essence of airborne particle counter signal transmission is changing particle's diameter distribute way to corresponding pulse signal amplitude distribute way with linear transform.All these establish the theoretical foundation for promoting the instrument's development toward the large flow and high sensitivity.
  • 加载中
  • [1]

    LIANG Ch L,HUANG H J,BEN B Q.Study of miniature optical sensot for laser particle counter[J].Acta Optica Sinica,2005,25 (9):1260-1264(in Chinese).
    [2]

    HUANG H J,ZHOU H X.Improvement on optics of optical particle counter[J].Optical Instruments,1994,16 (2):10-14 (in Chinese).
    [3]

    LI Z Y,LIU Zh Q,YE Y.Study on the effects of selection and process of the holography film for in-line particles holography[J].Laser Technology,2005,29 (6):617-620 (in Chinese).
    [4]

    BIAN B M,HE A Zh,WU D L.Reflexive speckle image of the point light source in the laser airborne particle counter for 0.1μm and its processing[J].Journal of Optcelectronics · Laser,1997,8 (4):246-250(in Chinese).
    [5]

    BIAN B M,HE A Zh,CHENG X F.Study of signal amplitude distribution for single particle in airborne particle counter[J].Journal of Southeast University,1999,29 (1):145-149 (in Chinese).
    [6]

    YANG L,CHENG X F,BIAN B M.The study of transmission of light scattering signal of particles[J].Journal of Optoelectronics · Laser,2000,11 (1):89-91 (in Chinese).
    [7]

    ZHOU L X,LI R,SHENG D F.PLC controlling stamping machine[J].Journal of Suzhou Institute of Silk Textile Technology,2005,21(3):45-49(in Chinese).
    [8]

    GAO Y F,ZOU L X,HUANG H J.Influence of the light source in airborne laser particle counter on the flux of transducer[J].Journal of Applied Optics,2005,26(3):45-49(in Chinese).
    [9]

    HAN G C,WANG Y W.The influence of two definitions for arbitrary particles on the shapo-affecter[J].Laser Technology,2003,27 (6):520-523(in Chinese).
    [10]

    REN Zh B,LU Zh W,LIU Y L.Study of Mie normalized scattered intensity distributions[J].Journal of Optoelectronics · Laser,2003,14(1):83-85 (in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3611) PDF downloads(386) Cited by()

Proportional views

The study of signal transmission characteristic in airborne particle counter

    Corresponding author: LU Jian, lujian@mai.lnjus.tedu.cn
  • 1. Department of Information Physics and Engineer, Nanjing University of Science and Technology, Nanjing 210094, China

Abstract: In order to study the essential characteristic of airborne particle counter signal transmission,some basic characteristics of airborne particle counter are studied with proceeding from single particle signal,including collecting characteristic of scattered light and photoelectric transfer characteristic.Based on these,statistics characteristic of signal distribute of single particle group and signal transmission characteristic of mixed particles group were analyzed.At the same time,the experiment was performed and the result is consistent with the theory with the correlation coefficient more than 0.9.Results indicate the essence of airborne particle counter signal transmission is changing particle's diameter distribute way to corresponding pulse signal amplitude distribute way with linear transform.All these establish the theoretical foundation for promoting the instrument's development toward the large flow and high sensitivity.