Time interval measurement of laser ranging based on CPLD & microchip

  • Corresponding author: YI Xiao-su, yixiaosu@buaa.edu.cn
  • Received Date: 2007-05-17
    Accepted Date: 2007-08-21
  • In order to improve the precision of time interval measurement in pulsed laser ranging,several interpolation methods are used.Analog interpolation time-interval measurement has advantages of high precision,small blind area,long measurement range and good linearity.Ananalog interpolation measurement method using complex programmable logic device(CPLD) and microchip was presented.Benefiting from the use of CPLD,the circuit became simplified.Furthermore,the time-interval measurement system adapted extraordinarily to high performance portable pulsed laser rangefinder for its compactness,simple structure and high reliability.
  • 加载中
  • [1]

    ZHANG L,QIN S Q,WANG S S,et al.Mini LD laser rangefinder used in intelligent vehicles[J].Laser Technology,2005,25(2):130-131(in Chinese).
    [2]

    YANG C W,CHEN Q S,LIN Y,et al.Measurement on time-interval in pulsed laser ranging and error analysis[J].Infrared and Laser Engineering,2003,32(2):123-126(in Chinese).
    [3]

    HONG Y J,CHEN Q S,PAN Z W.Review on time-of-flight measurement of pulsed laser radar[J].Laser and Infrared,2001,31(3):136-139(in Chinese).
    [4]

    LIU C J,YANG H J,LAI F.Technology of the rendezvous radar measuring the object's position[J].Laser Technology,2006,30(6):608-610(in Chinese).
    [5]

    XIE X S,FANG Y W,WU Y F,et al.Infrared laser ranging in auto adaptive cruise control system[J].Laser Technology,2004,28(5):521-523(in Chinese).
    [6]

    LI L,WANG Z Z,SHEN Y.Discussion on the signal processing ofhigh precision laser range finder[J].Laser and Infrared,2005,35(6):441-443(in Chinese).
    [7]

    LU Z M.Use of time interval measure system for laser ranging and the error analysis[J].Infrared and Laser Engineering,2001,20(3):37-39(in Chinese).
    [8]

    YANG C W,HUO Y J,HE S F,et al.The measurement of flight time for pulsed laser ranging based on CPLD[J].Laser and Infrared,2004,34(2):106-108(in Chinese).
    [9]

    Analog Devices Inc.High speed 8-Bit TTL A/D converter AD9012[DB/CD].Norwood,USA:Analog Devices Inc,1998-01-05.
    [10]

    SUN Y C,WANG R X,SUN H F.The new ATMEL's AT89S52 and its applications[M].Beijing:Tsinghua University Press,2004:31-46(in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(4563) PDF downloads(455) Cited by()

Proportional views

Time interval measurement of laser ranging based on CPLD & microchip

    Corresponding author: YI Xiao-su, yixiaosu@buaa.edu.cn
  • 1. School of Instrument Science & Opto-electronics Engineering, Beijing University of Aeronautics and Astronautics, Beijing 100083, China

Abstract: In order to improve the precision of time interval measurement in pulsed laser ranging,several interpolation methods are used.Analog interpolation time-interval measurement has advantages of high precision,small blind area,long measurement range and good linearity.Ananalog interpolation measurement method using complex programmable logic device(CPLD) and microchip was presented.Benefiting from the use of CPLD,the circuit became simplified.Furthermore,the time-interval measurement system adapted extraordinarily to high performance portable pulsed laser rangefinder for its compactness,simple structure and high reliability.