Advanced Search

ISSN1001-3806 CN51-1125/TN Map

Volume 30 Issue 2
Sep.  2013
Article Contents
Turn off MathJax

Citation:

Study on signal-to-noise ratio of drug-fluorescence imaging system

  • Received Date: 2005-01-07
    Accepted Date: 2005-05-19
  • The quantity value of signal and background light of fluorescence imaging system of nasopharyngeal carcinoma is calculated when photosensitizer is excited by the light at the wavelength of 488nm.In order to distinguish the signal from the background light,the light-transmission coefficient of a narrow-band filter must be as great as possible and noise must be reduced by a factor of 4.3×10-5.According to the absorption characteristic of colored glass,the ratio of signal transmission coefficient to background light transmission becomes large with optical-path increased suitably.If the thickness of the colored glass and the band width of the narrow-band filter now on hand is encreased properly,fine signal-to-noise ratio and resolving capability of fluorescence imaging can be obtained.
  • 加载中
  • [1]

    ZHENG W F,SU W J,LIB H et al.Optical and fluorescent characterization of porcine post-pharyngeal wall tissue at 488nm and 514.5nm[J].Journal of Optoelectronics · Laser,2004,15 (12):1506~1509(in Chinese).
    [2]

    LIBH,XIEShS,LINQRetal.Processing of pseudocolor display of lung cancer fluorescence image[J].Journal of Optoelectronics · Laser,1998,9 (6):495~498 (in Chinese).
    [3]

    PROFIO A E,DOIRON D R.Laser fluorescence bronchoscope for localization of occult lung tumors[J].Medical Physics,1979,6 (6):523~525.
    [4]

    LIB H,XIE Sh S.Preliminary study of diagnostic spectroscopic imaging for nasopharyngeal carcinoma[J].Proc SPIE,2003,5254:388~392.
    [5]

    YUN T,ZHENG W Y.Vision and visual mechanism[J].Yunguang Technology,1998,30 (4):17~33 (in Chinese).
    [6]

    ZHOU Ch Zh,LI B H,CHEN J et al.Design of fluorescence imaging for localizator of early nasopharyngeal carcinoma[J].Journal of Optoelectronics · Laser,2002,13 (6):639~642 (in Chinese).
    [7]

    ZHOU Ch Zh,XIE Sh S.Some problems of irradiation lesion simultaneously with low level CO2 laser and He-Ne laser[J].Laser Technology,1992,16(3):184~187(in Chinese).
    [8]

    XIE Sh S.Design of the optical phantom of tissue for photodynamic therapy research[J].Proc SPIE,1990,1616:246~251.
    [9]

    XIE Sh S,LIB Ho LU Z K.A new fluorescence imaging system for diagnosis and localization of nasopharyngeal cancinoma[J].Chinese Journal of Scientific Instrument,2004,25 (4):448~451 (in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3311) PDF downloads(332) Cited by()

Proportional views

Study on signal-to-noise ratio of drug-fluorescence imaging system

  • 1. School of Physics and Optoelectronics Technology, Fujian Normal University, Fuzhou 350007, China

Abstract: The quantity value of signal and background light of fluorescence imaging system of nasopharyngeal carcinoma is calculated when photosensitizer is excited by the light at the wavelength of 488nm.In order to distinguish the signal from the background light,the light-transmission coefficient of a narrow-band filter must be as great as possible and noise must be reduced by a factor of 4.3×10-5.According to the absorption characteristic of colored glass,the ratio of signal transmission coefficient to background light transmission becomes large with optical-path increased suitably.If the thickness of the colored glass and the band width of the narrow-band filter now on hand is encreased properly,fine signal-to-noise ratio and resolving capability of fluorescence imaging can be obtained.

Reference (9)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return