Advanced Search
XIE An-dong, SHI De-heng, CHEN Yu-ke, LIU Yu-fang. Temperature measurement sensitivity of a practical real-time temperature measurement system[J]. LASER TECHNOLOGY, 2004, 28(6): 625-629.
Citation: XIE An-dong, SHI De-heng, CHEN Yu-ke, LIU Yu-fang. Temperature measurement sensitivity of a practical real-time temperature measurement system[J]. LASER TECHNOLOGY, 2004, 28(6): 625-629.

Temperature measurement sensitivity of a practical real-time temperature measurement system

  • Based on the Kirchhoff law,a practical temperature real-time measurement system using laser diode InGaAs/I and LiTaO3 pyroelectric detector is presented.By means of analyzing the relationships among resolving power of A/D converter,temperature measurement sensitivity of V(T)-T curve and temperature measurement range,16bite A/D converter for this instrument is determined.According to the relationships among temperature measurement accuracy,relative temperature measurement sensitivity of V(T)-T curve and waveleng ths,further optimal wavelength is discussed.Based on the relationships among resolving power of the detector and A/D converter and temperature sensitivity of V(T)-T curve,further optimal wavelength bandwidth is analyzed.Temperature measurement sensitivity of the instrument at 673K~1473K is given.Temperature measurement sensitivity is above 0.5K at lower temperatures and above 0.1K at higher temperatures at 673K~1473K after using optimal parameters.Temperature measurement inaccuracy at 673K~1473K exceeds 0.3%.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return