Numerical analysis of CO2 DIAL measurement sensitivity

  • Received Date: 2003-09-15
    Accepted Date: 2003-11-14
  • For direct detection,long-range CO2 differential absorption lidar (DIAL) system,two factors which have effects on measurement sensitivity:atmospheric turbulence and laser speckle are analyzed.Numerical calculation results of the dependent relationship between measurement sensitivity and atmospheric turbulence and laser speckle are obtained.These results show that when the height is smaller than 350m,measurement sensitivity can be efficiently improved by increasing the height of equipment above ground;when the height is bigger than 350m,measurement sensitivity can be efficiently improved by changing system parameters.
  • 加载中
  • [1] PRASAD C R,KABRO P,MATHUR S.Tunable IR differential ab-sorption lidar remote sensing of chemicals[J].Proc SPIE,1999,3757:57:87~95.[2] WARREN R E.Optimum detection of multiple vapor materials with frequency-agile lidar[J].Appl Opt,1996,35:4180~4193.[3] PETRIN R R,NELSON D H,SCHMITT M J et al.Atmospheric effects on CO2 differential absorption lidar sensitivity[J].Proc SPIE,1996,2703.28~39.[4] 凯林格 D K穆拉迪 A.光和激光遥感[M].成都:成都电讯工程学院出版社,1987.23~28.[5] BELAND R R.THE INFRARED AND ELECTRO-OPTICAL SYSTEMS HANDBOOK[M].Michigan:Infrared Information Analysis Center,1993.157~232.[6] MacKERROW E P,TIEE J J,FITE C B et al.Laser speckle effects on hard target differential absorption lidar[J].Proc SPIE,1996,2702:65~83.[7] SCHMITT M,McVERY B,COOKE Bet al.Comprehensive system model for CO2 DIAL[J].Proc SPIE,1996,2702:95~103.

  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3400) PDF downloads(420) Cited by()

Proportional views

Numerical analysis of CO2 DIAL measurement sensitivity

  • 1. College of Electronic Engineering, University of Electronic Science and Technology of China, Chengdu 610054, China;
  • 2. Air Force Headquarter, Chengdu Military Area, Chengdu 610041, China

Abstract: For direct detection,long-range CO2 differential absorption lidar (DIAL) system,two factors which have effects on measurement sensitivity:atmospheric turbulence and laser speckle are analyzed.Numerical calculation results of the dependent relationship between measurement sensitivity and atmospheric turbulence and laser speckle are obtained.These results show that when the height is smaller than 350m,measurement sensitivity can be efficiently improved by increasing the height of equipment above ground;when the height is bigger than 350m,measurement sensitivity can be efficiently improved by changing system parameters.