Measurement of the ground state copper atom density in a magnetically confined discharge

  • Received Date: 1998-09-26
    Accepted Date: 1998-12-17
  • Using absorption method,we measured the ground state copper atom density in a magnetically confined discharge,and found that the density of the atom was the degree of 1014cm-3 ,and was suited to copper vapor laser action.Comparing with conventional copper vapor lasers,the discharge gas temperature was quite lower.So the results show the feasibility of applying the magnetically confined discharge in copper vapor lasers.
  • 加载中
  • [1]

    Li J,Chen Q M.J Phys D:Appl Phys,1993;26:1541
    [2]

    Chen Q M,Sun H,Zhou F Q et al.Two high power gas lasers excited by confined discharge.Proceedings of international conference on laser's 1993,Nevada:Tahoe,Lake,1993:241
    [3]

    Nerheim N M.J A P,1977;48(8):3244
    [4]

    Borovich B L,Vasiler L A,Gerts V E et al.Sov J Q E,1981;11(9):1210
    [5]

    Astadjov D N,Isaev A A,Petrash G G et al.IEEE J Q E,1992;QE-28(10):1966
    [6]

    Mitchell A C G,Zemanski M W.Radiation and Excited Atoms.London:Cambridge University Press,1961
    [7]

    Taylor L H,Feldman R B.J A P,1979;50(5):3212
    [8]

    Honig R E.RCA Rev,1963;28:567
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3327) PDF downloads(264) Cited by()

Proportional views

Measurement of the ground state copper atom density in a magnetically confined discharge

  • 1. State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan, 430070;
  • 2.  2. National Laboratory of Laser Technology, HUST, Wuhan, 430074

Abstract: Using absorption method,we measured the ground state copper atom density in a magnetically confined discharge,and found that the density of the atom was the degree of 1014cm-3 ,and was suited to copper vapor laser action.Comparing with conventional copper vapor lasers,the discharge gas temperature was quite lower.So the results show the feasibility of applying the magnetically confined discharge in copper vapor lasers.

Reference (8)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return