Study of polarization maintaining fiber ring resonator

  • Received Date: 1998-01-20
  • A kind of polarization maintaining fiber ring resonator used in fiber ring resonator sensor for angular velocity measurement is reported in this paper.The measurement principle is based on Sagnac effect.So the system is composed of a laser with narrow spectra,fiber resonator,detector and other control circuits.According to the numerical calculation and experimental results,several important optical parameters,which have influence on the performance of system,are analyzed and optimized.Now the fiber ring resonator has been adopted in the sensor system.
  • 加载中
  • [1]

    Ezeliel,Balsamo S R.A P L,1977;30:478~480
    [2]

    Meyer R E,Ezekiel S,Stowe D W et al.Opt Lett,1983;8(12):644~646
    [3]

    Kaiser T J,Cardarelii D et al.SPIE,1990;1367:121~126
    [4]

    Iwat suki K,Hotate K,Higoshiguchi M.Appl Opt,1986;25(15):2606~2612
    [5]

    Takiguchi K,Hotate K.Method to reduce the optical Kerr-effect induced bias in an optical passivering resonatorgyro. Proc.of 8th Optical Fiber Sensors Conference,Monterey,CA,1992:34~37
    [6]

    Carroll R,Coccoli C D,Cardarelli D et al.S PIE,1986;719
    [7]

    Zhang F,Lit J W Y.Optical Society of America,1988;A 5(8):1347~1356
    [8]

    Takiguchi K,Hotate K.IEEE photonics technology letters,1991;3(1):88~90
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3528) PDF downloads(437) Cited by()

Proportional views

Study of polarization maintaining fiber ring resonator

  • 1. Department of Precision Instrument and Mechanics, Tsinghua University, Beijing, 100084

Abstract: A kind of polarization maintaining fiber ring resonator used in fiber ring resonator sensor for angular velocity measurement is reported in this paper.The measurement principle is based on Sagnac effect.So the system is composed of a laser with narrow spectra,fiber resonator,detector and other control circuits.According to the numerical calculation and experimental results,several important optical parameters,which have influence on the performance of system,are analyzed and optimized.Now the fiber ring resonator has been adopted in the sensor system.