Experimental research of using OPO to replace dye laser in CARS thermometry

  • Received Date: 1997-01-02
    Accepted Date: 1997-03-12
  • Ordinary,the dye laser is used as a stokes light source in CARS thermometry.But the dye laser has the features of bad output stabilization and big size,so we employ OPO to replace the dye laser as the stokes light source of the CARS measurement system to realize the miniaturization of the system.This paper discusses the feasibility from the theoretical and practical analysis and points out that it is feasible at the range of less 2200K.
  • 加载中
  • [1]

    Hall R J.O pt Engng,1983;22(3):322
    [2]

    Bruggeman D,Hertzberg J,Wies B et al.A ppl Phys,1992;B55:378
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3248) PDF downloads(348) Cited by()

Proportional views

Experimental research of using OPO to replace dye laser in CARS thermometry

  • 1. Jilin University of Technology, Changchun, 130025

Abstract: Ordinary,the dye laser is used as a stokes light source in CARS thermometry.But the dye laser has the features of bad output stabilization and big size,so we employ OPO to replace the dye laser as the stokes light source of the CARS measurement system to realize the miniaturization of the system.This paper discusses the feasibility from the theoretical and practical analysis and points out that it is feasible at the range of less 2200K.