Advanced Search

ISSN1001-3806 CN51-1125/TN Map

Volume 21 Issue 3
Sep.  2013
Article Contents
Turn off MathJax

Citation:

Using A/D converter to improve precision of time interval measurement in pulse laser range finder

  • Received Date: 1996-01-22
    Accepted Date: 1996-05-15
  • In view of the problem that the count quantization error affects on the precision of time interval measurement in pulse laser range finding,a method to improve the precision using A/D is put forward and its feasibility and precision is analyzed in this paper.It is proved through theory analysis and test that this method can be easily realized to decrease the count quantization error by several order.
  • 加载中
  • [1] 魏余灵,于善智,刘家鸣et al.电子测量与仪器学报,1993;7(1):54~63

    [2] 沈兰荪.数据采集技术合肥:中国科学技术大学出版社,1990

  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3241) PDF downloads(462) Cited by()

Proportional views

Using A/D converter to improve precision of time interval measurement in pulse laser range finder

  • 1. Anhui Institute of Optics and Fine Mechanics, Academia Sinica, Hefei, 230031

Abstract: In view of the problem that the count quantization error affects on the precision of time interval measurement in pulse laser range finding,a method to improve the precision using A/D is put forward and its feasibility and precision is analyzed in this paper.It is proved through theory analysis and test that this method can be easily realized to decrease the count quantization error by several order.

Reference (2)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return