Advanced Search
Yang Jincai, Liu Fu, Jin Cang, Lan Hong. An on line detection method of flaw of chain element slice using He-Ne laser[J]. LASER TECHNOLOGY, 1996, 20(6): 356-359.
Citation: Yang Jincai, Liu Fu, Jin Cang, Lan Hong. An on line detection method of flaw of chain element slice using He-Ne laser[J]. LASER TECHNOLOGY, 1996, 20(6): 356-359.

An on line detection method of flaw of chain element slice using He-Ne laser

More Information
  • Received Date: March 10, 1996
  • Revised Date: July 21, 1996
  • Published Date: November 24, 1996
  • This paper presents an optical method to detect the flaw of chain slice.The information of flaw is detected from the change of intensity distribution of diffuse reflection light from the round edge slice illuminated by a He-Ne laser and recorded with a CCD camera.The theoretical width and maximum deviation of diffuse reflection light are calculated and the position confined condition of CCD camera is given.The experimental results show that the device is simple in structure and easy to operate and able to select the shortcoming slices rapidly and automatically.
  • [1]
    王俊华,崔砚生,吴美娟编著.激光原理及应用.北京:清华大学出版社,1987:117~123
    [2]
    Tenkins F A,White H E著,杨光熊,郭永康译.光学基础(下册).北京:高等教育出版社,1994:152~158
    [3]
    纪明.长春光学精密机械学院学报,1991;14(2):1~5
  • Related Articles

    [1]TAN Yuan, GAN Xuehui, ZHANG Dongjian, LIU Xiangyu, LIAO He. Laser Doppler vibration signal processing based on wavelet denoising[J]. LASER TECHNOLOGY, 2022, 46(1): 129-133. DOI: 10.7510/jgjs.issn.1001-3806.2022.01.014
    [2]ZHAO Yang, JIN Guangyong, LI Mingxin, ZHANG Wei, WANG Di. Experimental study about CCD detectors damaged by millisecond pulsed laser[J]. LASER TECHNOLOGY, 2017, 41(5): 632-636. DOI: 10.7510/jgjs.issn.1001-3806.2017.05.003
    [3]ZHANG Fan, NIU Yanxiong, LIU Ning, LIANG Zhenjiang, LIU Shuai. Research of temperature field and thermal stress field of CCD under laser irradiation[J]. LASER TECHNOLOGY, 2017, 41(3): 433-437. DOI: 10.7510/jgjs.issn.1001-3806.2017.03.025
    [4]JI Changpeng, ZHAO Lina. Research of wave filter method of human sphygmus signal[J]. LASER TECHNOLOGY, 2016, 40(1): 42-46. DOI: 10.7510/jgjs.issn.1001-3806.2016.01.010
    [5]SHI Ying, JU Ai-song, LE Yan-fen. 基于FPGA的外差干涉信号处理方法[J]. LASER TECHNOLOGY, 2012, 36(2): 221-224. DOI: 10.3969/j.issn.1001-3806.2012.02.020
    [6]YANG Liu-sha, LIU Jin-shui, LIU Ji-chang, WU Yao-ting, WANG Ying-li. Study on CCD-based detection system for online monitoring of melt pool width in laser cladding[J]. LASER TECHNOLOGY, 2011, 35(3): 315-318. DOI: 10.3969/j.issn.1001-3806.2011.03.008
    [7]QIU Xiao-qian, LE Yan-fen, WANG Jing. Interpolation of heterodyne interferometric signals based On FPGA[J]. LASER TECHNOLOGY, 2011, 35(2): 199-201,205. DOI: 10.3969/j.issn.1001-3806.2011.02.016
    [8]LIU Sheng-gang, LI Ze-ren, LIU Qiao. Study of self-mixing interference signal processing based on time-frequency analysis[J]. LASER TECHNOLOGY, 2009, 33(6): 626-629. DOI: 10.3969/j.issn.1001-3806.2009.06.019
    [9]Hu Linting, Lu Xiankui, Jin Junkun, Han Fuli. Laser facula measurement with CCDQ[J]. LASER TECHNOLOGY, 2001, 25(2): 154-157.
    [10]Zhang Tieqiang, Guo Shanhe, Shen Xuanguo. Measurement of divergent angle width of laser beam with CCD for determination of radius of curvature of cylindrical lens[J]. LASER TECHNOLOGY, 1996, 20(5): 266-268.

Catalog

    Article views (0) PDF downloads (14) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return