Advanced Search

ISSN1001-3806 CN51-1125/TN Map

Volume 38 Issue 3
Mar.  2014
Article Contents
Turn off MathJax

Citation:

Application of fast inversion algorithm in measurement of steam humidity of steam turbine

  • Corresponding author: HUANG Zhuqing, huangzhuqing@aliyun.com
  • Received Date: 2013-05-27
    Accepted Date: 2013-06-21
  • In order to solve the problem confronted with the online steam humidity measurement of turbine flow pass, a semi-empirical formula of phase function computing method was proposed to improve the inversion algorithm on scattering light distribution. Phase function of double Gaussian fitting by using MATLAB with cftool was adopted in this algorithm. The fitting result shows that the relative error is in small, and the approximate analytic solution of the Mie scattering theory could be got by the fitting function, which means that a rapid inversion from the scattering light intensity distribution to water quality radius. According to the results, with the restriction of the range of the droplet size, the approximation of the theory between the droplet size and scattering ratio was got. Contrast experiment showed the measured scattering ratio was similar with the simulated scattering ratio. Based on the semi-empirical model, the water quality of middle radius was 1.1μm.The fast inversion algorithm can well resolve the online measurement of steam humidity.
  • 加载中
  • [1]

    KADONO T, ARAKAWA M, KOUCHIC A.Size distributions of chondrules and dispersed droplets caused by liquid breakup:An application to shock wave conditions in the solar nebula [J].Icarus, 2008,197(2):621-626.
    [2]

    SIGEL R.Light scattering near and from interfaces using evanescent wave and ellipsometric light scattering[J].Colloid & Interface Science, 2009,14(6):426-437.
    [3]

    GOGOI A, BURAGOHAIN A K, CHOUDHURY A, et al. Laboratory measurements of light scattering by tropical fresh water diatoms[J].Journal of Quantitative Spectroscopy & Radiative Transfer, 2009,110(14/16):1566-1578.
    [4]

    SHCHERBAKOV A A, TISHCHENKO A V. Light scattering in plane dielectric layers: modeling in the 2-D reciprocal space[J].Journal of Quantitative Spectroscopy & Radiative Transfer,2012,113(18):2424-2430.
    [5]

    WU W, QIN Sh Q, HUANG Zh Q.A fast inversion method for water droplet size determination in scattering light measurement[J].Journal of Optics, 2011,31(7):1-5(in Chinese).
    [6]

    HUANG Zh Q, YANG J M, SUN Ch Sh. Application of the laser scattering theory for monitoring steam wetness and droplet size in steam turbines[J].Journal of Power Engineering,2006,26(2):241-244(in Chinese).
    [7]

    CAI W W, ZHAO Y,MA L. Direct recursion of the ratio of Bessel functions with applications to Mie scattering calculations[J].Journal of Quantitative Spectroscopy & Radiative Transfer,2008,109(16):2673-2678.
    [8]

    HUANG Zh Q,QIN Sh Q. Investigation of exhaust wetness measurement method in steam turbine based on mie scattering of laser[D].Changsha: Graduate School of National University of Defense Technology,2010:1-118(in Chinese).
    [9]

    ZHANG H Y, ZHAO W J, REN D M, et al. Improved algorithm of Mie scattering parameter based on MATLAB[J].Journal of Light Scattering,2008,20(2):102-110(in Chinese).
    [10]

    GODDEERIS C, CUPPO F, REYNAERS H, et al. Light scattering measurements on microemulsions:estimation of droplet sizes[J].International Journal of Pharmaceutics, 2006,312(1/2):187-195.
    [11]

    HUANG Zh Q, CAO X L, YANG J M, et al. Application of CCD in measuring steam moisture and droplet size [J].Opto-Electronic Engineering, 2010, 37(4):39-43(in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3704) PDF downloads(560) Cited by()

Proportional views

Application of fast inversion algorithm in measurement of steam humidity of steam turbine

    Corresponding author: HUANG Zhuqing, huangzhuqing@aliyun.com
  • 1. School of Energy and Power Engineering, Changsha University of Science & Technology, Changsha 410114, China;
  • 2. Hunan Nonferrous Metals Vocational and Technical College, Zhuzhou 412006, China

Abstract: In order to solve the problem confronted with the online steam humidity measurement of turbine flow pass, a semi-empirical formula of phase function computing method was proposed to improve the inversion algorithm on scattering light distribution. Phase function of double Gaussian fitting by using MATLAB with cftool was adopted in this algorithm. The fitting result shows that the relative error is in small, and the approximate analytic solution of the Mie scattering theory could be got by the fitting function, which means that a rapid inversion from the scattering light intensity distribution to water quality radius. According to the results, with the restriction of the range of the droplet size, the approximation of the theory between the droplet size and scattering ratio was got. Contrast experiment showed the measured scattering ratio was similar with the simulated scattering ratio. Based on the semi-empirical model, the water quality of middle radius was 1.1μm.The fast inversion algorithm can well resolve the online measurement of steam humidity.

Reference (11)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return