Research of on-line film thickness measurement system based on infrared dual-light path

  • Corresponding author: ZHAO Bin, zhaobin63@sohu.com
  • Received Date: 2013-05-10
    Accepted Date: 2013-06-13
  • Infrared thickness measurement is one of the main methods of online film thickness measurement, but traditional infrared thickness measurement method still has such defects that it is sensitive to the stability of light source and it is not applicable to high-speed film production line. In order to solve these problems, a dual-light path reference measurement method was used and a dual-light path infrared thickness measurement system was presented. In the system, the light source is divided into measurement light path and reference light path, using a single CCD connecting both the measurement light and the reference light as light intensity sensor. The imaging principle was described and the applicability of the system for Lambert law was discussed. Finally, calibration experiments for polyethylene and polytetrafluoroethylene film were conducted to demonstrate the accuracy. The experimental results show that the method has high precision and good robustness, and can effectively avoid the impact of the unstable of light source.
  • 加载中
  • [1]

    WANG Ch, ZHAO B. Research of thin plate thickness measurement based on single lens laser triangulation[J]. Laser Technology,2013,37(1):6-10(in Chinese).
    [2]

    ZHANG M H. Uses of the infrared technology for on-line gauging of plastic film thickness[J]. Journal of Zhejiang University of Technology, 1985(2):1-8(in Chinese).
    [3]

    LIAO F Z, WEI H R, ZHAO W K,et al. A non-contact method for measuring the thickness of polyester film with infrared absorption[J]. Acta Metrologica Sinica, 1990,11(4):266-270(in Chinese).
    [4]

    WORKMAN J, WEYER L. Practical guide to interpretive near-infrared spectroscopy[M]. 2nd ed. Boca Raton,Florida, USA: Chemical Rubber Company Press, Inc., 2012: 12-16.
    [5]

    MENG F F, WANG T W, ZHANG Q T. Preparation and performance analysis of near-infrared absorption PVB films[J]. Infrared and Laser Engineering, 2012, 41(11): 3003-3007(in Chinese).
    [6]

    JOHNSON J, HARRIS T. Full-field optical thickness profilometry of semitransparent thin films with transmission densitometry[J]. Applied Optics,2010, 49(15): 2920-2928.
    [7]

    MARTINEZ ANTON J C,GOMEZ PEDRERO J A,ALONSO FERNANDEZ J, et al. Optical method for the surface topographic characterization of Fresnel lenses[J]. Proceedings of SPIE, 2011,8169:816910.
    [8]

    CHEN W, HU K T. Study on sheet formation with computer visual system[J].World Pulp and Paper, 2000, 19(3):48-50(in Chinese).
    [9]

    QU E Sh, ZHANG H J, CAO J Zh, et al. Discussion of illuminance formula in optical design[J].Acta Optica Sinica, 2008,28(7):1364-1368(in Chinese).
    [10]

    YU D Y, TAN H Y.Engineering optics[M]. Beijing: Press of Mechanical Industry, 2011: 82-83(in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3998) PDF downloads(923) Cited by()

Proportional views

Research of on-line film thickness measurement system based on infrared dual-light path

    Corresponding author: ZHAO Bin, zhaobin63@sohu.com
  • 1. Department of Instrument Science and Technology, College of Mechanical Science and Enginnering, Huazhong University of Science and Technology, Wuhan 430074, China

Abstract: Infrared thickness measurement is one of the main methods of online film thickness measurement, but traditional infrared thickness measurement method still has such defects that it is sensitive to the stability of light source and it is not applicable to high-speed film production line. In order to solve these problems, a dual-light path reference measurement method was used and a dual-light path infrared thickness measurement system was presented. In the system, the light source is divided into measurement light path and reference light path, using a single CCD connecting both the measurement light and the reference light as light intensity sensor. The imaging principle was described and the applicability of the system for Lambert law was discussed. Finally, calibration experiments for polyethylene and polytetrafluoroethylene film were conducted to demonstrate the accuracy. The experimental results show that the method has high precision and good robustness, and can effectively avoid the impact of the unstable of light source.

Reference (10)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return