Advanced Search

ISSN1001-3806 CN51-1125/TN Map

Volume 37 Issue 3
Mar.  2013
Article Contents
Turn off MathJax

Citation:

Acquisition of photoelastic modulator interferometer data and spectrum recovery

  • In order to obtain the frequency spectrum of a photoelastic modulator interferometer,it needs spectrum recovery.Because of the nonlinear phase,the effect of spectrum recovery is poor by using the fast Fourier transform,so the non-uniform fast Fourier transform algorithm was proposed for spectrum recovery of the interference data.Firstly,the interference data with 652.6nm laser passing through the photoelastic modulator interferometer was obtained by the virtual oscilloscope based on high-speed data acquisition card PCI-5122.Then,the spectrum interference data was recovered with Matlab software.The recovery results show that the wavelength measurement error of the collected 652.6nm laser data is less than 1nm,the recovered error is less than 0.1%,which verifies the feasibility of the algorithm for the spectrum recovery of non-uniform photoelastic modulation interference data and have reference value for the design of high-performance photoelastic modulator-Fourier transform spectrometer.
  • 加载中
  • [1]

    KEMP J C.Piezo-optical birefringence modulators:new use for a long-known effect[J].Journal of the Optical Society of America,1969,59(8):950-953.
    [2]

    CANIT J C,BADOZ J.New design for a photoelastic modulator[J].Applied Optics,1983,22(4):592-594.
    [3]

    YANG D,CANIT J C,GAIGNEBET E.Photo-elastic modulator:polarization modulation and phase modulation[J].Journal of Optics(Paris),1995,26(4):152-159.
    [4]

    COOLEY J W,TUKEY J W.An algorithm for the machine calculation of complex Fourier series[J].Mathematics of Compputation,1965,19(90):297-301.
    [5]

    XUE H,ZHANG L,LIU Y N.Overview of nonuniform fast Fourier transformation[J].Computerized Tomography Theory and Applications,2010,19(3):33-46(in Chinese).
    [6]

    FESSLER J A,SUTTONB B P.Nonuniform fast fourier transforms using min-max interpolation[J].IEEE Transactions on Signal Processing,2003,51(2):560-574.
    [7]

    LIU Q H,NGUYEN N.An accurate algorithm for nonuniform fast Fourier transform(NUFFT's)[J].IEEE Microwave and Guided Wave Letters,1998,8(l):18-20.
    [8]

    JING J J,XIANGLI B,LÜ Q B.Analysis on spectrum recovery for nonuniform sampling interferogram[J].Acta Optica Sinica,2011,31(12):1211006(in Chinese).
    [9]

    YANG X X,ZHOU S Zh,XIANGLI B,et al.Studies on nonlinearity of optical path difference of rotary Fourier transform spectrometer[J].Acta Optica Sinica,2004,24(10):1388-1392(in Chinese).
    [10]

    YAO T,LÜ Q B,XIANGLI B,et al.Comparison of correction methods for nonlinear optic path difference of reflecting rotating Fourier transform spectrometer[J].Spectroscopy and Spectral Analysis,2010,30(6):1678-1682(in Chinese).
    [11]

    HU C G,SUN L D,LI Y N,et al.Retardation correction for photoelastic modulator based multi-channel reflectance difference spectroscopy[J].Journal of the Optical Society of America,2008,25(6):1240-1245.
    [12]

    YIN Sh M,XIANGLI B,ZHOU J S,et al.Real-time data processing of interferential imaging spectrometer based on FPGA[J].Journal of Infrared Millimeter Waves,2007,26(4):274-278(in Chinese).
    [13]

    WU Z Ch,ZHANG T H.Signal acquisition and processing based on PXI-6225[J].Instrumentation Technology,2010(4):16-18(in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3688) PDF downloads(563) Cited by()

Proportional views

Acquisition of photoelastic modulator interferometer data and spectrum recovery

    Corresponding author: ZHANG Ji-long, wangzhibin@nuc.edu.cn
  • 1. Engineering and Technology Research Center of Shanxi Province for Optical-Electric Information and Instrument, North University of China, Taiyuan 030051, China;
  • 2. Key Laboratory of Instrument Science & Dynamic Measurement of Ministry of Education, North University of China, Taiyuan 030051, China

Abstract: In order to obtain the frequency spectrum of a photoelastic modulator interferometer,it needs spectrum recovery.Because of the nonlinear phase,the effect of spectrum recovery is poor by using the fast Fourier transform,so the non-uniform fast Fourier transform algorithm was proposed for spectrum recovery of the interference data.Firstly,the interference data with 652.6nm laser passing through the photoelastic modulator interferometer was obtained by the virtual oscilloscope based on high-speed data acquisition card PCI-5122.Then,the spectrum interference data was recovered with Matlab software.The recovery results show that the wavelength measurement error of the collected 652.6nm laser data is less than 1nm,the recovered error is less than 0.1%,which verifies the feasibility of the algorithm for the spectrum recovery of non-uniform photoelastic modulation interference data and have reference value for the design of high-performance photoelastic modulator-Fourier transform spectrometer.

Reference (13)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return