Advanced Search
ZONG Peng-fei, WANG Zhi-bin, ZHANG Ji-long, CHEN Yuan-yuan. Study on baseline fitting method based on passive infrared range measurement[J]. LASER TECHNOLOGY, 2013, 37(2): 174-177. DOI: 10.7510/jgjs.issn.1001-3806.2013.02.009
Citation: ZONG Peng-fei, WANG Zhi-bin, ZHANG Ji-long, CHEN Yuan-yuan. Study on baseline fitting method based on passive infrared range measurement[J]. LASER TECHNOLOGY, 2013, 37(2): 174-177. DOI: 10.7510/jgjs.issn.1001-3806.2013.02.009

Study on baseline fitting method based on passive infrared range measurement

More Information
  • Received Date: July 23, 2012
  • Revised Date: August 19, 2012
  • Published Date: March 24, 2013
  • In order to measure the range accurately and calculate the transmittance precisely with infrared spectrum passive ranging technology,baseline was fitted with interpolation method. Taking oxygen A band as an example, baseline fitting was completed through a variety of interpolation fitting methods making use of both sides of the absorption data from line-by-line radiative transfer model. Meanwhile, detail theoretical analysis and simulation verification were carried out, after comparing several algorithms, the accuracy of polynomial interpolation fitting is the best. The implementation of baseline fitting algorithm provides method for establishing a database of transmittance, distance and other conditions and provides a solid foundation for realization of passive ranging.
  • [1]
    HE T, NIU Y X, ZHANG P, et al. Study on active laser detection distance[J]. Laser Technology, 2012, 36(2): 217-220(in Chinese).
    [2]
    HAWKS M R. Passive ranging using atmospheric oxygen absorption spectra. Ohio, USA: Air Force Institute of Technology, 2006: 8-30.
    [3]
    MAcDONALD D J. Passive ranging using infrared atmospheric attenuation[J]. Infrared Technology and Applications,2009, 7660(41):1-9.
    [4]
    WARK D Q, MERCER D M. Absorption in the atmosphere by the oxygen ‘A' band [J].Applied Optics, 1965, 4(7):839-845.
    [5]
    VINCENT R. Passive ranging of dynamic rocket plumes using infrared and visible oxygen attenuation. Ohio, USA: Air Force Institute of Technology,2011: 3-25.
    [6]
    HAWKS M R. Passive ranging of emissive targets using atmospheric oxygen absorption lines[J].Proceedings of SPIE,2005,5811:112-122.
    [7]
    ZHANG H, SHI G Y. A fast and efficient line-by-line calculation method for atmospheric absorption[J]. Chinese Journal of Atmospheric Sciences,2000,24(1):112-122(in Chinese).
    [8]
    HUANG Y D, AN J B. A nonuniformity correction algorithm for IRFPA based on improved polynomial fitting[J]. Infrared,2011,32(3):29-33(in Chinese).