Effect of convergent light on polarization measurement

  • Corresponding author: FENG Wei-wei, fwwclg@126.com
  • Received Date: 2010-09-19
    Accepted Date: 2010-10-11
  • In order to obtain the rule of polarization measurement error caused by the phenomena of convergent light in a polarization camera,based on three dimensional polarization ray tracing calculi,the effect of transmitted polarized intensity parallel to optical axis on the measurement accuracy of polarization degree was studied.Simulation results show that the measured degree of polarization is always less than the real polarization degree due to the convergence of light,and polarization measurement error increases with the convergent angular.It is also indicated that for a certain light convergent state and polarization measurement condition,the larger the polarization degree of incident light,the bigger the polarization measurement error.
  • 加载中
  • [1]

    SUN X B,HONG J,QIAO Y L.A method ofimage feature extraction based angle of polarization[J].Remote Sensing Technology Application,2005,20(2):256-260(in Chinese).
    [2]

    QIAO Y L,YANC Sh Zh,LUO R Zh,et al.Research on polarned spectral monitoring for remote sensing of earth[J].High Technology Letters,2001,11(7):36-39 (in Chinese).
    [3]

    DESCHAMPS P Y,HERMAN M,PODAIRE A,et al.The POLDER instrument:misaion objectives[J].Proceedings of SPIE,1992,1746:72-91.
    [4]

    DEUZE J L,BREON F M,DESCHAMPS P Y,et al.Polarization measurements with the airbome version of the POLDER instrument[J].Ptoceedings of SPIE,1992,1747:178-187.
    [5]

    DINER D J,CHIPMAN R A.An integrated multiangle,multispectral,and polarimetric imaging concept for aerosol remote sensing from space[J].Proceeding of SPIE,2005,5659:88-96.
    [6]

    DEUZE J L,GOLOUB P,HERMAN M,et al.Aerosol retrieval using the POLDER instrument preliminary results[J].Ptoceedings of SPIE,1997,3121:347-355.
    [7]

    CAIRNS B,EDCAR E R,JOSEPH D L,et al.Research scanning polarimeter and airbome usage for remote sensing of aeroaols[J].Proceedings of SPIE,2003,5158:33-44.
    [8]

    TRAVIS L D.Remote sensing of aerosols with the earth obsewing scanning polarimeter[J].Proceedings of SPIE,1992,1747:154-164.
    [9]

    CHEN L G,HONG J,QIAO Y L,et al.Accuracy analysis on a sort of polarized measurement in remote sensing[J].Spectroscopy and Spectral Analysis,2008,28(10):2384-2387 (in Chinese).
    [10]

    LUO R Z,QIAO Y L,DUAN L F.Polarization analysis of optical system in airborne multi-band polarization CCD camera system[J].Proceedings of SPIE,2003,4891:442-448.
    [11]

    WALUSCHKA E,SILVERCIATE P,FTACLAS C,et al.Polarization sensitivity analysis of an earth remote sensing instrument:the MODIS-N Phase B study[J].Proceedings of SPIE,1992,1746:96-103.
    [12]

    CAO H,SONG L K,PENC H D,et al.The study of the relationship between polarized light's incident azimuth and intermediary reflectance[J].Laser Technology,2005,29(1):104-105 (in Chinese).
    [13]

    CHEN L G,HONG J,QIAO Y L,et al.Accuracy analysis of polarimetric measurement based on double Wollaston prisms[J].Laaer Technology,2008,32(5):468-470 (in Chinese).
    [14]

    CHIPMAN R A,The mechanics of polartion ray tracing[J].Proceedings of SPIE,1992,1746:62-75.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(5116) PDF downloads(866) Cited by()

Proportional views

Effect of convergent light on polarization measurement

    Corresponding author: FENG Wei-wei, fwwclg@126.com
  • 1. Institute of Theoretical Physics, Department of Physics and Electronics Science, Binzhou University, Binzhou 256603, China;
  • 2. Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China

Abstract: In order to obtain the rule of polarization measurement error caused by the phenomena of convergent light in a polarization camera,based on three dimensional polarization ray tracing calculi,the effect of transmitted polarized intensity parallel to optical axis on the measurement accuracy of polarization degree was studied.Simulation results show that the measured degree of polarization is always less than the real polarization degree due to the convergence of light,and polarization measurement error increases with the convergent angular.It is also indicated that for a certain light convergent state and polarization measurement condition,the larger the polarization degree of incident light,the bigger the polarization measurement error.

Reference (14)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return