Calibration of PMP system using virtual planes

  • Received Date: 2009-07-13
    Accepted Date: 2009-09-20
  • In order to calibrate the coefficients of phase-height mapping equation in phase measuring profilometry (PMP) systems,virtual planes were introduced. Firstly,the intrinsic and extrinsic parameter, of camera and projector were calibrated with uniforni mathematics model and processing method,as a projector could be considered as a camera working in reverse.Secondly,geometric construction of the measurement system was calibrated by means of stereovisiou method.Thirdly, a reference plane was defined in the measuring volume.Phase distribution of reference plan and parallel standard planes at different distances from the reference plan was worked out according to the calibrated parameters.Finally, the coefficients of phase-height mapping equation were obtained with least square method.The standard deviation of measurement reached 0.046mm.A model consists of four steps with space of 1.00mm was also measured. The measured average height between neighbor steps was 0.99mm.The experiment results reveal that the method is feasible.The procedure of system calibration is simplified.
  • 加载中
  • [1]

    CHEN F,BROWN G M,SONG M.Overview of three-dimensional shape measurement using optical methods[J].Opt Engng,2000,39(1):10-22.
    [2]

    BLAIS F.Review of 20 years of range sensor development[J].Journal Electron Imaging,2004,13(1):231-240.
    [3]

    MA L H,WANG H,LI Y,et al.3-D rebuilding based on numerical reconstruction of the hologram[J].Acta Photonica Sinica,2006,35(4):595-598(in Chinese).
    [4]

    YONEYAMA S,MORIMOTO Y,FUJIGAKI M,et al.Phase-measuring profilometry of moving object without phase-shifting device[J].Optics and Lasers in Engineering,2003,40(3):153-161.
    [5]

    ZHOU W S,SU X Y.A direct mapping algorithm for phase-measuring profilometry[J].Journal of Modern Optics,1994,41(1):89-94.
    [6]

    SU X Y,SONG W Z,CAO Y P,et al.Phase-height mapping and coordinate calibration simultaneously in phase-measuring profilometry[J].Opt Engng,2004,43(3):708-712.
    [7]

    ZHANG Z Y.A flexible new technique for camera calibration[J].IEEE Transactions on Pattern Analysis and Machine Intelligence,2000,22(11):1330-1334.
    [8]

    ZHANG J,ZHU D Y,JIA X D.Camera lens distortion calibration with co-line points[J].Laser Technology,2006,30(2):221-224(in Chinese).
    [9]

    HEIKKILA J,SILVEN O.A four-step camera calibration procedure with implicit image correction[C]//Proceedings of IEEE Computer Society Conference on Computer Vision and Pattern Recognition.Washington D C:IEEE Computer Society,1997:1106-1112.
    [10]

    LI Y,SU X Y,WU Q Y.Accurate phase-height mapping algorithm for PMP[J].Journal of Modern Optics,2006,53(14):1955-1964.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(5306) PDF downloads(270) Cited by()

Proportional views

Calibration of PMP system using virtual planes

  • 1. Institute of Information Optics, Zhejiang Normal University, Jinhua 321004, China;
  • 2. Tianjin Professional College, Tianjin 300402, China;
  • 3. Department of Automotive Engineering, Military Traffic Institute, Tianjin 300161, China

Abstract: In order to calibrate the coefficients of phase-height mapping equation in phase measuring profilometry (PMP) systems,virtual planes were introduced. Firstly,the intrinsic and extrinsic parameter, of camera and projector were calibrated with uniforni mathematics model and processing method,as a projector could be considered as a camera working in reverse.Secondly,geometric construction of the measurement system was calibrated by means of stereovisiou method.Thirdly, a reference plane was defined in the measuring volume.Phase distribution of reference plan and parallel standard planes at different distances from the reference plan was worked out according to the calibrated parameters.Finally, the coefficients of phase-height mapping equation were obtained with least square method.The standard deviation of measurement reached 0.046mm.A model consists of four steps with space of 1.00mm was also measured. The measured average height between neighbor steps was 0.99mm.The experiment results reveal that the method is feasible.The procedure of system calibration is simplified.

Reference (10)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return