Study on stray facula of array CCD detector irradiated by laser pulse

  • Received Date: 2009-12-08
    Accepted Date: 2010-03-31
  • In order to investigate the stray facula in the in-line digital hologram with an array CCD detector irradiated by short intense laser pulse,variable images were gathered with CCD under laser irradiation or not.Different image grey was analyzed based on the diffraction fringes of the particles and the output electrical signal of the pixel.The stray facula was induced by diffracting dust in the pixels and the abnormal behavior of the reset level due to laser absorption of CCD.Without laser irradiation,the image gathered by CCD was quite abnormal due to the thermal effect and memory effect of CCD.The results showed that the stray facula vanished slowly with the elimination of heat during a long time.Finally,the image gathered by CCD can recover normally and the stray facula vanished completely when the dirty was removed and the time interval of the gathering image was prolonged.
  • 加载中
  • [1]

    KREIS T,ADAMS M,JüPTNER W.Digital in-line holography in particle measurement[J].SPIE,1999,3744:54-64.
    [2]

    PEDRINI G,GUSEV M,SCHEDIN S,et al.Pulsed digital holographic interferometry by using a flexible fiber endoscope[J].Optics and Lasers in Engineering,2003,40(5/6):487-499.
    [3]

    LUO Zh X,LI Z R,LIU Zh Q,et al.Application of in-line digital holography to micro-jet particles measurement[J].Explosion and Shock Waves,2007,27(3):278-282(in Chinese).
    [4]

    LI Z B,ZHENG G,ZHANG L X,et al.Influence of some parameters for particle diameter measurement using digital in-line holography[J].Opto-electronic Engineering,2008,35(8):24-29(in Chinese).
    [5]

    WANG L,FENG S T,NIE S P,et al.Single exposure 3-D object digital holography based on multi-filtering technique[J].Laser Technology,2007,31(4):354-357(in Chinese).
    [6]

    ZHOU J M,FU Y Y,GUO J,et al.Research on the soft damage of CCD induced by pulse laser[J].Laser Journal,2005,26(2):20-21(in Chinese).
    [7]

    CAO Y L,GAO Ch Q.Analysis on the accuracy of beam parameter measurement by using CCD array[J].Optical Technique,2004,30(5):583-586(in Chinese).
    [8]

    ZHANG Zh,CHENG X G,JIANG Z F.Excessive saturation effect of visible light CCD[J].High Power Laser and Particle Beams,2008,20(6):917-920(in Chinese).
    [9]

    LIU Z J,LU Q S,JIANG Zh P,et al.Study of damage effect in CCD detectors irradiated locally by laser[J].Laser Technology,1994,18(6):344-347(in Chinese).
    [10]

    LIU T H,ZHONG H R,LU Q S,et al.Study on mechanism of laser damage in photoelectric detectors[J].Laser Journal,2001,22(6):5-8(in Chinese).
    [11]

    JIANG N,ZHANG Ch,NIU Y X.Numerical simulation of pulsed laser induced damage on CCD arrays[J].Laser Infrared,2008,38(10):1004-1007(in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(4965) PDF downloads(245) Cited by()

Proportional views

Study on stray facula of array CCD detector irradiated by laser pulse

  • 1. Insititute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China;
  • 2. National Key Laboratory of Shock Wave and Denotation Physics, Insititute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China

Abstract: In order to investigate the stray facula in the in-line digital hologram with an array CCD detector irradiated by short intense laser pulse,variable images were gathered with CCD under laser irradiation or not.Different image grey was analyzed based on the diffraction fringes of the particles and the output electrical signal of the pixel.The stray facula was induced by diffracting dust in the pixels and the abnormal behavior of the reset level due to laser absorption of CCD.Without laser irradiation,the image gathered by CCD was quite abnormal due to the thermal effect and memory effect of CCD.The results showed that the stray facula vanished slowly with the elimination of heat during a long time.Finally,the image gathered by CCD can recover normally and the stray facula vanished completely when the dirty was removed and the time interval of the gathering image was prolonged.