Measurement of tuning wavelength of frequency-doubled Nd:YAG laser by means of reference spectrum

  • Received Date: 2008-10-25
    Accepted Date: 2008-11-04
  • In order to measure the tuning wavelength of a frequency-doubled Nd:YAG laser,strong absorption lines of molecular iodine near 532nm was adopted to provide the absolute reference for frequency stabilization.The experiment system for measuring wavelength was built up with iodine vapor as reference,and the iodine vapor absorption lines were measured.Compared with the computed absorption lines,the relations between laser tuning frequency and voltage,laser tuning frequency and rotary angle of potentiometer were obtained,the mode hop was found,and the tuning range of frequency-doubled Nd:YAG laser was measured.The results show that it is a suitable method for measuring tuning wavelength of frequency-doubled Nd:YAG laser by means of iodine vapor absorption lines.
  • 加载中
  • [1]

    ZANG E J,CAO J P,ZHONG M Ch,et al.Stable second harmonic generation using a monolithic ring laser and an external ring cavity[J].Acta Optica Sinica,2003,23(3):33-340(in Chinese).
    [2]

    KANE T J,BYER R L.Monolithic unidirectional single-modeNd:YAG ring laser[J].Opt Lett,1985,10(2):65-67.
    [3]

    ARIE A,BYER R.Laser heterodyne spectroscopy of 127I2 hyperfine structure near 532nm[J].J O S A,1993,B10(11):1990-1997.
    [4]

    HONG F L,ISHIKAWA J.Hyperfine structures of the R(122)35-0 and p(84)33-0 transitions of 127I2 near 532nm[J].J Opt Commun,2000,183(1/4):101-108.
    [5]

    LI J,BAI X D.The parameters optimization of Doppler broadened iodine at 532nm Nd:YVO4 laser frequency stabilization[J].Laser Technology,2003,27(1):50-52(in Chinese).
    [6]

    ZANG E J,CAO J P,LI Y,et al.532nm iodine molecular optical frequency standards[J].Chinese Journal of Laser,2007,34(2):203-208(in Chinese).
    [7]

    HALL J L,MA L S,TAUBMAN M,et al.Stabilization and frequency measurement of the I2-stabilized Nd:YAG laser[J].IEEE Transactions on Instrumentation and Measurement,1999,48(2):583-586.
    [8]

    FORKEY J N,LEMPERT W R,MILES R B,et al.Corrected and calibrated I2 absorption model at frequency-doubled Nd:YAG laser wavelengths[J].Appl Opt,1997,36(27):6729-6738.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(5223) PDF downloads(191) Cited by()

Proportional views

Measurement of tuning wavelength of frequency-doubled Nd:YAG laser by means of reference spectrum

  • 1. Northwest Institute of Nuclear Technology, Xi'an 710024, China

Abstract: In order to measure the tuning wavelength of a frequency-doubled Nd:YAG laser,strong absorption lines of molecular iodine near 532nm was adopted to provide the absolute reference for frequency stabilization.The experiment system for measuring wavelength was built up with iodine vapor as reference,and the iodine vapor absorption lines were measured.Compared with the computed absorption lines,the relations between laser tuning frequency and voltage,laser tuning frequency and rotary angle of potentiometer were obtained,the mode hop was found,and the tuning range of frequency-doubled Nd:YAG laser was measured.The results show that it is a suitable method for measuring tuning wavelength of frequency-doubled Nd:YAG laser by means of iodine vapor absorption lines.

Reference (8)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return