高级检索

用粒子计数法测量颗粒物质量浓度

顾芳, 杨娟, 卞保民, 贺安之

顾芳, 杨娟, 卞保民, 贺安之. 用粒子计数法测量颗粒物质量浓度[J]. 激光技术, 2007, 31(4): 360-363.
引用本文: 顾芳, 杨娟, 卞保民, 贺安之. 用粒子计数法测量颗粒物质量浓度[J]. 激光技术, 2007, 31(4): 360-363.
GU Fang, YANG Juan, BIAN Bao-min, HE An-zhi. Measurement of particle mass concentration using particle counter method[J]. LASER TECHNOLOGY, 2007, 31(4): 360-363.
Citation: GU Fang, YANG Juan, BIAN Bao-min, HE An-zhi. Measurement of particle mass concentration using particle counter method[J]. LASER TECHNOLOGY, 2007, 31(4): 360-363.

用粒子计数法测量颗粒物质量浓度

详细信息
    作者简介:

    顾芳(1981- ),女,博士研究生,主要从事颗粒测试和光学传感器技术方面的研究.

    通讯作者:

    贺安之,E-mail:haz@mail.njust.edu.cn

  • 中图分类号: O436.2

Measurement of particle mass concentration using particle counter method

  • 摘要: 为了测量颗粒物的质量浓度,基于米散射理论,在偏振入射光条件下,通过数值计算研究了球形颗粒的散射光通量与粒径之间的关系,得到了利用光学粒子计数器测量颗粒物质量浓度的计算公式。该公式重点考虑了粒子数目和大小对质量浓度的影响。实验结果表明,在0.001mg/m3~2mg/m3的质量浓度范围内,该公式的计算值与实验测量值具有显著的相关性,相关系数为0.9953。
    Abstract: In order to measure the mass concentration of particulate matter,according to Mie scattering theory,the relationship between scattered light flux and spherical particle diameter was discussed under the condition of polarized light input,then the formula was attained for calculating particle mass concentration by means of optical particle counter.And particle size distribution was considered using the formula to calculate mass concentration.The experimental results indicate that,in the range of 0.001mg/m3~2mg/m3,calculated mass concentration by the formula and measured mass concentration by a photometer (TSI SIDEPAK AM510) are highly correlated,the correlation coefficient is 0.9953.
  • [1]

    CHUEINTA W,HOPKE P K.Beta gauge for aerosol mass measure-ment[J].Aerosol Science and Technology,2001,35(4):840~843.

    [1]

    NORBERT E.Fine particles and human health-a review of epidemiological studies[J].Toxicology Letters,2004,149(2):235~242.

    [2]

    SOUTAR A,WATT M,CHERRIE J W et al.Comparison between a personal PM10 sampling head and the tapered element oscillating microbalance (TEOM) system[J].Atmospheric Environment,1999,33(27):4373~4377.

    [3]

    GMITERKO A,SLOSARCIK S,DOVICA M.Algorithm of nonrespirable dust fraction suppression using an optical transducer of dust mass concentration[J].IEEE Transactions on Instrumentation and Measurement,1998,47(5):1228~1233.

    [4]

    SHENG D R.Research on evaluation of air-solid two phase particledistribution and mean concentration by laser scattering[J].Laser Technology,2000,24(3):163~166(in Chinese).

    [5]

    YAN F Q,HU H L,YU T.Measurement of particulate mass concentrations and atmospheric visibility with an optical particle counter[J].Chinese Journal of Quantum Electronics,2004,21(1):98~102(in Chinese).

    [6]

    GAO Y F,ZOU L X,HUANG H J et al.Influence of the light source in airborne laser particle counter on the flux of transducer[J].Journal of Applied Optics,2005,26(3):45~49(in Chinese).

    [7]

    BOHTEN C F,HUFFMAN D R.Absorption and scattering of light bysmall particles[M].New York:John Wiley & Sons,1983.1~533.

    [8]

    ZHU D Y,WU Ch O,QIN W L.Multiple statistical analysis and software SAS[M].2nd ed,Nanjing:Southeast University Press,2003.257~270(in Chinese).

    [9]

    SIOUTAS C,KIM S,CHANG M Ch et al.Field evaluation of a modified DataRAM MIE scattering monitor for real-time PM2.5 mass

计量
  • 文章访问数:  1
  • HTML全文浏览量:  0
  • PDF下载量:  7
  • 被引次数: 0
出版历程
  • 收稿日期:  2006-06-22
  • 修回日期:  2006-11-13
  • 发布日期:  2007-08-24

目录

    /

    返回文章
    返回