高级检索

基于虚拟仪器的光声信号采集和成像系统

何军锋, 谭毅, 姚军财

何军锋, 谭毅, 姚军财. 基于虚拟仪器的光声信号采集和成像系统[J]. 激光技术, 2008, 32(5): 558-560.
引用本文: 何军锋, 谭毅, 姚军财. 基于虚拟仪器的光声信号采集和成像系统[J]. 激光技术, 2008, 32(5): 558-560.
HE Jun-feng, TAN Yi, YAO Jun-cai. Photoacoustic signal collecting and image reconstructing system based on virtual instruments[J]. LASER TECHNOLOGY, 2008, 32(5): 558-560.
Citation: HE Jun-feng, TAN Yi, YAO Jun-cai. Photoacoustic signal collecting and image reconstructing system based on virtual instruments[J]. LASER TECHNOLOGY, 2008, 32(5): 558-560.

基于虚拟仪器的光声信号采集和成像系统

基金项目: 

陕西理工学院院上资助项目(SLG0721);陕西省教育厅资助项目(06JK330)

详细信息
    作者简介:

    何军锋(1972- ),男,讲师,主要研究方向为光声层析成像在医学中的应用.E-mail:hejunfeng@snut.edu.cn

  • 中图分类号: Q-334

Photoacoustic signal collecting and image reconstructing system based on virtual instruments

  • 摘要: 为了实现光声信号的快速采集和图像重建,采用基于虚拟仪器的光声信号采集和成像系统进行光声信号采集,由LABVIEW调用MATLAB程序对采集到的数据进行处理,最后利用滤波反投影重建算法,实现了对模拟组织样品的光声层析成像。成像系统的分辨率为0.15mm,重建图像与实物十分吻合。结果表明,该系统具有快速、方便、直观等特点,有望发展成为一种低成本的实用的临床诊断仪器。
    Abstract: In order to collect photoacoustic signals and reconstruct images quickly,photoacoustic signal collecting and image reconstructing system based on virtual instrument is applied to collect photoacoustic signals.Then the program of MATLAB is used to process collected data by LABVIEW.The photoacoustic imaging of phantom is obtained with filtered back projection algorithm in the end.The resolution of reconstructed image is 0.15mm.The reconstructed image is corresponded well with phantom.The methodology and equipment show that this imaging system features high speed and convenience.Furthermore,it is likely to be developed into a cheaper and practical clinical diagnosis instrument.
  • [1]

    ZHU H H,ZUO D L,CHENG Z H,et al.Experiment research of acoustic effect induced by pulsed CO2 laser in water[J].Laser Technology,2006,30(6):605-607(in Chinese).

    [2] TAN Y,HE J F.Photoacoustic imaging consideration of ultrasonic refraction[J].Journal of Optoelectronics稬aser,2007,18(8):1013-1016(in Chinese).
    [3]

    SUZUKI K,YAMASHIITA Y,OHTA K,et al.Quantitative measurement of optical parameters in normal breasts using time-resolved spectroscopy in vivoresults of 30 Japanese women[J].Journal of Iomedical Optics,1996,1(3):330-334.

    [4]

    ZHANG H F,MASLOV K,WANG L H,et al.Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging[J].Nature Biotechnology,2006,24(7):848-851.

    [5]

    KU G,WANG L H.Deeply penetrating photoacoustic tomography in biological tissues enhanced with an optical contrast agent[J].Opt Lett,2005,30(5):507-509.

    [6]

    SU Y X,WANG R K,ZHANG F,et al.Two-dimensional photoacoustic imaging of blood vessel networks within biological tissues[J].Chinese Physics Letters,2006,23(2):512-515.

    [7]

    WANG X D,PANG Y J,KU G,et al.Noninvasive laser induced photoacoustic tomography for structural and functional in vivo imaging of the brain[J].Nature Biotechnology,2003,21(7):803-806.

    [8]

    SIPHANTO R I,THUMMA K K,KOLKMAN R G M,et al.Serial noninvasive photoacoustic imaging of neovascularization in tumor angiogenesis[J].Optics Express,2005,13(1):89-95.

    [9]

    CHEN Z X,TANG Z L,WAN W,et al.Photoacoustic tomography imaging based on a 4f acoustic lens imaging system[J].Optics Express,2007,15(8):4966-4976.

    [10]

    YIN B Z,XING D,WANG Y,et al.Fast photoacoustic imaging system based on 320-element linear transducer array[J].Physics in Medicine and Biology,2004,49(7):1339-1346.

    [11]

    ZENG Y G,XING D,WANG Y,et al.Photoacoustic and ultrasonic Co-image with a linear transducer array[J].Opt Lett,2004,29(15):1760-1762.

    [12]

    YANG D W,XING D,TAN Y,et al.Integrative prototype B-scan photoacoustic tomography system based on a novel hybridized scanning head[J].A P L,2006,88(17):174101-174103.

    [13]

    XU M H,WANG L V.Time-domain reconstruction for thermoacoustic tomography in a spherical geometry[J].IEEE Transactions on Medical Imaging,2002,21(7):814-822.

    [14]

    HE J F,TAN Y.Development of photoacoustic imaging technology in biomedicine[J].Laser Technology,2007,31(5):530-533(in Chinese).

    [15]

    ZENG L M,XING D,GU H M,et al.High antinoise photoacoustic tomography based on a modified filtered backprojection algorithm with combination wave[J].Medical Physics,2007,34(2):556-563.

计量
  • 文章访问数:  5
  • HTML全文浏览量:  0
  • PDF下载量:  2
  • 被引次数: 0
出版历程
  • 收稿日期:  2007-08-23
  • 修回日期:  2007-11-12
  • 发布日期:  2008-10-24

目录

    /

    返回文章
    返回