  • Received Date: 1994-04-25
  • The purpose of the paper is to introduce a coherence extender and the experimental study of the device.The extender is slanting Fabry-Perot etalon.used in the resonator of the domestic argon-ion laser.With the coherence extender,the co-herence length of argon-ion laser can come from 5cm up to several meters and the power loss is the range of 25%~40%, The device can be used in the field of coherence detection.
  • 加载中
  • [1] 赵凯华,钟锡华.光学.北京:北京大学出版社,1984:330-340

    [2]

    Signore R. Instruments et Laboratoires, 1971;(1):7-14
    [3]

    Hercher M. Appl Opt,1969:8(6):1103-1106
    [4]

    Корояев ф А et al.ЖПС,1976:25 (6):990-994
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3647) PDF downloads(247) Cited by()

Proportional views

A coherence extender for the domestic argon-ion lasers

  • 1. Department of Applied Physics, Tsinghua University

Abstract: The purpose of the paper is to introduce a coherence extender and the experimental study of the device.The extender is slanting Fabry-Perot etalon.used in the resonator of the domestic argon-ion laser.With the coherence extender,the co-herence length of argon-ion laser can come from 5cm up to several meters and the power loss is the range of 25%~40%, The device can be used in the field of coherence detection.