Research of measurement of wet steam parameters with off-axis angular scattering method

  • Corresponding author: HUANG Zhuqing, huangzhuqing@aliyun.com
  • Received Date: 2013-06-06
    Accepted Date: 2013-06-25
  • In order to monitor the density and distribution of water-drop at the end stage of the steam turbine, the off-axis angular scattering method was proposed to measure the parameters of wet steam. In this way, it not only guides economic operation of the turbine but also guarantee water allowance of the boiler. At the same time, it can reduce the influence of wet steam on the turbine. Based on the structure and parameters of mock cylinder, a mathematic model was built. This mathematic model can find whether the middle radius of quantity, the density of number and the distribution of magnitude in water-drop have impact on the scattering ratio. The wet steam was measured under different conditions. The analysis result was similar to the experimental result. The experimental results proved the off-axis angular scattering method is feasible for measuring wet steam parameters. This research is helpful for monitoring the parameters of wet steam and other particles.
  • 加载中
  • [1]

    HUANG Zh Q,YANG J M,SUN C Sh, et al. Application of the laser scattering theory for monitoring steam wetness and droplet size in steam turbines[J].Journal of Power Engineering,2006,26(2):241-244(in Chinese).
    [2]

    ZHOU L X, ZHANG M Zh,WANG S L,et al.Situation and development of steam wetness measurement in turbine exhaust casing[J].Journal of North China Electric Power University,2001,28(2):72-76(in Chinese).
    [3]

    WANG L L,CAI X Sh.Progress in research on water droplet size in two phase wet steam flow in steam turbine[J].Journal of University of Shanghai for Science and Technology,2003,25(4):307-311(in Chinese).
    [4]

    HUANG T L,ZHENG G,WANG N N.Theory study of light scattering measurement technology on particulate contamination under ultraclean environment[J].Journal of Guilin Institute of Electronic Technology,2000,20(1):6-12(in Chinese).
    [5]

    ITO S.Optical wave propagation in discrete random media with large particles a treatment of the phase function[J]. Applied Optics,1993,32(9):1652-1656.
    [6]

    LENTZ W J.Generating Bessel funtions in Mie scattering calculations using continued fractions[J].Applied Optics,1976,15(3):668-671.
    [7]

    DAVE J V. Coefficients of the legendre and Fourier series for the scattering functions of spherical particles[J].Applied Optics,1970,9(8):1888-1896.
    [8]

    BAYVEL L P, JONES A R.Electromagnetic scattering and its applications[M].London,UK:Applied Science Press,1981:26-27.
    [9]

    ZHANG B D,QIN Sh Q,JIA H J,et al. Measurement model and uncertainty analysis of pulsed laser far field energy density based on CCD imaging[J].High Power Laser and Particle Beams,2008,20(9):1417-1920(in Chinese).
    [10]

    ZHONG J,WENG J D,LUO Zh X,et al.Study on stray facula of array CCD detector irradiated by laser pulse[J].Laser Technology,2010,34(6):835-838(in Chinese).
    [11]

    SU P,NIU Y X,LI D Q,et al.Image acquisition and processing of a laser warning system based on planar array CCD[J].Laser Technology,2013,37(3):394-399(in Chinese).
    [12]

    WANG Q Y.Application technology of CCD [M].Tianjing:Tianjing University Press,2000:17-27(in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3618) PDF downloads(558) Cited by()

Proportional views

Research of measurement of wet steam parameters with off-axis angular scattering method

    Corresponding author: HUANG Zhuqing, huangzhuqing@aliyun.com
  • 1. School of Energy and Power Engineering, Changsha University of Science & Technology, Changsha 410114, China;
  • 2. Hunan Nonferrous Metals Vocational and Technical College, Zhuzhou 412006, China

Abstract: In order to monitor the density and distribution of water-drop at the end stage of the steam turbine, the off-axis angular scattering method was proposed to measure the parameters of wet steam. In this way, it not only guides economic operation of the turbine but also guarantee water allowance of the boiler. At the same time, it can reduce the influence of wet steam on the turbine. Based on the structure and parameters of mock cylinder, a mathematic model was built. This mathematic model can find whether the middle radius of quantity, the density of number and the distribution of magnitude in water-drop have impact on the scattering ratio. The wet steam was measured under different conditions. The analysis result was similar to the experimental result. The experimental results proved the off-axis angular scattering method is feasible for measuring wet steam parameters. This research is helpful for monitoring the parameters of wet steam and other particles.

Reference (12)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return