Improvement method of measuring object deformation by using double-exposure with gray-level
-
1.
Institute of Laser, School of Science, Kunming University of Science and Technology, Kunming 650093, China
-
Corresponding author:
GONG Ai-ling, ailinggong@sina.com
;
-
Received Date:
2010-11-30
Accepted Date:
2011-01-29
-
Abstract
The usual method for recording and processing hologram images is digital holography, which is also suitable for double-exposure to measuring object deformation. However, the deformation near half of the optical wavelength is based on phase-shift method, and it needs more than three hologram images. In order to simplify the method, the double-exposure with gray-level was extended to measure deformation. By using the gray-level, with the image of gray-level distributions, the fringe numbers can be calculated and then the out-of-plane displacement was obtained. This method only needs take two images. Through theoretical analysis and experimentation, the result is satisfactory, which show this method works well in a certain extent.
-
-
References
[1]
|
LI J P,CAI Y L.Measurement of displacement direction by using reference-object holographic method[J].Laser Journal,2002,23(3):41-43(in Chinese). |
[2]
|
LI G Ch,GENG Y H,REN D Q,et al.Measurement of deformation direction of object by auxiliary plate micro-angle-displacement modulation holographic method[J].Chinese Journal of Science Instrument,2004,25(4):477-480( in Chinese). |
[3]
|
YU Q T,LV X X,ZHANG Q Sh.A new method of four-step phase-shifting digital hologram based on arbitrary phase shifts[J].Laser Technology,2009,33(4):409-412(in Chinese). |
[4]
|
KUMAR U P,MOHAN N K,KOTHIYAL M P.Measurement of static and vibrating microsystems using microscopic TV holography[J].Optik,2011,122(1):49-54. |
[5]
|
XIONG B H,LI J Ch.Holographic interference measurement--principles and methods[M].Beijing:Science Press,2009:323-337(in Chinese). |
[6]
|
GORTHI S S,RASTOGI P.Simultaneous measurement of displacement,strain and curvature in digital holographic interferometry using high-order instantaneous moments[J].Optics Express,2009,17(20):17784-17791. |
[7]
|
LV P,CHEN Zh M,WANG X,et al.Measuring density distribution of jet subsonic flow field based on dual hologram interferometry[J].Applied Laser,2009,29(3):219-222(in Chinese). |
[8]
|
YANG K,LIU Zh,WANG W Sh.Study on object displacement measure using double-exposure digital image hologram method[J].Journal of Changchun University of Science and Technology,2009,9(1):25-27(in Chinese). |
[9]
|
PRABHUNE V B,SHINDE N S,FULARI V J.Studies on electrodeposited silver sulphide thin films by double exposure holographic interferometry[J].Applied Surface Science,2008,255(5):1819-1823. |
[10]
|
THOKALE R N,PATIL P S,DONGARE M B.Double-exposure holographic interferometry technique used for characterization of electrodeposited cobalt oxide thin films[J].Materials Chemistry and Physics,2002,74(2):143-149. |
[11]
|
CHIEN C H,WU Y D,CHIOU Y T,et al.Nanoscale deformation measurement by using the hybrid method of gray-level and holographic interferometry[J].Optic and Laser in Engineering,2006,44(1):80-91. |
[12]
|
SU X Y,LI J T.Information optics[M].Beijing:Science Press,1999:111-156(in Chinese). |
[13]
|
FAN M X,ZHANG Y A,LI Zh F.Application of reflecting real-time digital holography in thermal stress field of rock[J].Laser Technology,2010,34(4):502-505(in Chinese). |
-
-
Proportional views
-