[1] |
TANG W B. Research on dynamic response rule of thermocouple for one type of turboprop engines combustor[D]. Nanjing: Nanjing University of Aeronautics and Astronautics, 2013: 15-40(in Chinese). |
[2] |
LIU Y, WU Sh, ZHAO Y G. Research and developing status on temperature sensor of thermocouple[J]. China Instrumentation, 2003, 23(11):1-3(in Chinese). |
[3] |
ZHAO Y Sh, YANG L H. Research progress of thin film thermocoupletemperature sensor[J]. Transducer and Microsystem Technologies, 2012, 31(2):1-3(in Chinese). |
[4] |
LIU H. Discussion on thermocouple temperature measurement principle and its application[J]. Science-Technology & Enterprise, 2014, 23(2):258(in Chinese). |
[5] |
FANG L D, ZHANG J K, WANG N, et al. Study of dynamic response on characteristics of K-type thermocouple[J]. Electronic Measurement Technology, 2010, 24(11):18-20(in Chinese). |
[6] |
WU F, YANG X Y, WANG L. Study on measuring time constants of surface temperature sensors[J]. Measurement Technique, 2014, 58(4):60-62(in Chinese). |
[7] |
TASHIRO Y, BIWA T, YAZAKI T.Calibration of a thermocouple for measurement of oscillating temperature.Review of Scientific Instruments, 2005, 76(12):24901-24905. |
[8] |
WANG S T, ZHAO J, JIN Zh T. Uncertainty analysis of time constant measurement of sapphire fiber blackbody cavity[J].Industrial Measurement, 2013, 23(3):53-54(in Chinese). |
[9] |
YANG Y, HAO X J, WU Y Y. Nonlinear fitting method based on dynamic calibration of thermocouples[J]. Laser Technology, 2014, 38(2):145-148(in Chinese). |
[10] |
WANG R, HAO X J, ZHOU H Ch, et al. Design of infrared signal detection circuit in a temperature calibration system[J]. Laser Technology, 2013, 37(2):247-250(in Chinese). |
[11] |
MA X Y, WANG J, LIU S P. Research and application of domestic high power semiconductor lasers[J]. Infrared and Laser Engineering, 2008, 37(2):189-194(in Chinese). |
[12] |
LIU B, HUANG Zh H, CAI H Y, et al.Design of driving system of quasi continuous wave laser diode based on differential amplifier circuit[J]. Laser Technology, 2015, 39(2):166-169(in Chinese). |
[13] |
HAO X J, ZHOU H Ch, LI K J. Application of CO2 laser to response time measurement to surface[J]. Chinese Journalof Scientific Instrument, 2007, 28(6):1040-1044(in Chinese). |
[14] |
QI M Y, DING J, YANG S L, et al.Simulation research on thin-film thermocouple temperature sensor dynamic character calibration[J]. Computer Simulation, 2016, 33(6):325-330(in Chinese). |
[15] |
TENG Sh L, KONG X M. Test system of time constant based on step temperature response[J]. China Measurement & Test, 2011, 37(1):24-27(in Chinese). |
[16] |
XU L X, XIE J B, YANG Zh W, et al. Preparation of micro thermocouple and calibration method of time constant[J]. Journal of Electronic Test and Instrument, 2016, 30(7):1023-1028(in Chinese). |