Advanced Search

ISSN1001-3806 CN51-1125/TN Map

Volume 31 Issue 5
May  2010
Article Contents
Turn off MathJax

Citation:

Simulation research on detecting thickness of CO2 by micro pulse DIAL

  • Corresponding author: HU Yi-hua, yh_hu@263.net
  • Received Date: 2006-08-28
    Accepted Date: 2006-11-22
  • In order to study the efficiency of detecting thickness of CO2 in low space by differential absorption lidar(DIAL),the detection principle and the SNR(signal to noise ratio) of the system were analyzed.With the simulation experiments of a kind of near-infrared micro pulse lidar with energy of 20μJ and repetition rate of 10kHz,the relation among the SNR,the needed accumulation time and detection distance was calculated.The results show that without regard to the background noise(working at night),the thickness of CO2 can be detected below 4.5km.Whereas,with regard to the background noise(working in daylight),the thickness of CO2 can only be detected below 2.4km.The conclusion is drawn that working at night and with other better performance instruments can increase the detection distance.
  • 加载中
  • [1]

    HU Sh X,HU H L,ZHOU J.DIAL lidar measurement for tropospheric ozone[J].Laser Technology,2001,25(6):406~408(in Chinese).
    [2]

    YIN Sh R,WANG W R,LI X Sh.Numerical analysis of CO2 DIAL measurement sensitivity[J].Laser Technology,2004,28(5):503~505(in Chinese).
    [3]

    SUN J Q.Atmosphere detection by laser[M].Beijing:Science Press,1986.1~269(in Chinese).
    [4]

    YAN J X,GONG Sh Sh,LIU Zh Sh.Laser radar in environment inspection[M].Beijing:Science Press,2001.1~231(in Chinese).
    [5]

    SPINHIRNE J.Micro pulse lidar[J].IEEE Transactions on Geoscience and Remote Sensing,1993,31(1):48~55.
    [6]

    HONG G L,ZHANG Y Ch,HU Sh X.Near infrared micro pulse lidar of profiling atomospheric CO2[J].Journal of Infrared Millimeter Waves,2004,23(5):384~388(in Chinese).
    [7]

    SASANO Y,KOBAYASHI T.Feasibility study on space lidars for measuring global atmospheric environment,No.4 Final Report,F-82-95[R].Tsukuba,Japanese:National Institute for Environmental Studies,1995.22~30.
    [8]

    HENRIKSSON M.Detection probabilities for photon-counting ava-lanche photodiodes applied to a laser radar system[J].Appl Opt,2005,44(6):5140~5146.
    [9]

    COVA S,LACAITA A,ZAPPA F et al.Avalanche photodiodes fornear-infrared photo-counting[J].Proc SPIE,1995,2388:56~65.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3602) PDF downloads(428) Cited by()

Proportional views

Simulation research on detecting thickness of CO2 by micro pulse DIAL

    Corresponding author: HU Yi-hua, yh_hu@263.net
  • 1. Electronic Engineering Institute of PLA, Hefei 230037, China;
  • 2. Anhui Provincial Key Laboratory of Electronic Restriction, Hefei 230037, China

Abstract: In order to study the efficiency of detecting thickness of CO2 in low space by differential absorption lidar(DIAL),the detection principle and the SNR(signal to noise ratio) of the system were analyzed.With the simulation experiments of a kind of near-infrared micro pulse lidar with energy of 20μJ and repetition rate of 10kHz,the relation among the SNR,the needed accumulation time and detection distance was calculated.The results show that without regard to the background noise(working at night),the thickness of CO2 can be detected below 4.5km.Whereas,with regard to the background noise(working in daylight),the thickness of CO2 can only be detected below 2.4km.The conclusion is drawn that working at night and with other better performance instruments can increase the detection distance.

Reference (9)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return