The optical transfer function of a fluorescent confocal microscope with extended Gaussian source

  • Received Date: 2004-08-09
    Accepted Date: 2004-12-15
  • The influence of the three parameters,namely the beam size of Gaussian source,the source size and the detector size,on the three-dimensional optical transfer function(3-D OTF) of an incident light fluorescent confocal microscope is investigated,and the 3-D OTF of such a set-up is derived.The calculated results show that the beam size has an effect on choosing both the source size and the detector size by means of a gaussian beam with the smaller beam size,both the source size and the detector size can be increased,and better optical resolution and higher signal-noise-ratio can be reached,compared with those by means of a parallel beam.
  • 加载中
  • [1] 唐志列,梁瑞生,朱小松 et al.偏振共焦扫描激光显微镜的成像特性研究[J].光学学报,1999,19(8):1118~1122.

    [2]

    HELL S W,BOOTH M,WILMS S.Two-photon near-and far-field fluorescence microscopy with continuous-wave excitation[J].Opt Lett,1998,23(15):1238~1240.
    [3]

    CUMPSTEM B H,ANANTHAVEL S P,BARLOW S et al.Two-photon polymerization initiators for three-dimensional optical data storage andmicrofabrication[J].Nature,1999,398(4):51~54.
    [4]

    SUN H B,MATSUO S,MISAWA H.Three-dimensional photonic crystal strutures achieved with two-photon-absorption photopolymerization of resin[J].A P L,1999,74(6):786~788.
    [5] 裴红津,唐志列,杨初平 et al.荧光波长对共焦显微镜成像特性的影响[J].光学学报,2002,22(10):1219~1223.

    [6] 唐志列,黄佐华,梁瑞生 et al.共焦显微镜的纵向分辨率及其判据[J].量子电子学报,2000,17(3):199~204.

    [7] 张平,吴震,王翠英 et al.荧光共焦扫描系统成像特性的优化[J].光学学报,1997,17(3):308~313.

    [8] 唐志列,杨初平,裴红津 et al.双光子共焦显微镜的三维成像理论与分辨率改善[J].中国科学,2002,A32(6):538~547.

    [9] 李爱民,陶纯堪,刘明 et al.共焦扫描激光显微镜的研制[J].激光技术,1994,18(5):261~263.

    [10] 张平,向际鹰,吴震.共焦扫描激光显微镜的电子控制系统研究[J].激光技术,1997,21(5):284~287.

    [11] 唐志列,梁瑞生,常鸿森.双光子和多光子共焦显微镜的成像理论[J].物理学报,2000,49(6):1076~1080.

    [12]

    GU M.Principles of three-dimensional imaging in confocal microscopies[M].Singapare:World Scientific,1996.1~10.
    [13]

    DRAZIC V.Three-dimensional transfer function analysis of a confocal fluorescence microscope with a finite-sized source and detector[J].J Mod Opt,1993,40(5):879~887.
    [14]

    DRAZIC V.Three-dimensional transfer function of coherent confocal microscopes with extended source and detector[J].J Mod Opt,1992,39(8):1777~1790.
    [15] 黄菁,梁瑞生,司徒达 et al.高斯光束共焦扫描激光显微镜的光学传递函数[J].物理学报,1998,47(8):1289~1294.

  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(2741) PDF downloads(356) Cited by()

Proportional views

The optical transfer function of a fluorescent confocal microscope with extended Gaussian source

  • 1. College of Sciences, South China Agricultural University, Guangzhou 510642, China

Abstract: The influence of the three parameters,namely the beam size of Gaussian source,the source size and the detector size,on the three-dimensional optical transfer function(3-D OTF) of an incident light fluorescent confocal microscope is investigated,and the 3-D OTF of such a set-up is derived.The calculated results show that the beam size has an effect on choosing both the source size and the detector size by means of a gaussian beam with the smaller beam size,both the source size and the detector size can be increased,and better optical resolution and higher signal-noise-ratio can be reached,compared with those by means of a parallel beam.

Reference (15)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return