Abstract
This paper reports the selection of the measurement spots and animal radiant exposure with the computer procedure control,under the outdoor condition,and the injury and safety bounds derived in terms of the double-track method of dosage measurements and animal experiments.The results of application show that the bounds presented in this paper are accurate.
-
-