Tomography of transient three-dimensional temperature field by moire deflectometry
- Received Date: 1990-02-22
- Available Online: 1990-11-25
Abstract: The tomography principle of 3-D temperature field by moire deflectometry is discussed. A multipth moire deflectometry is presented which is used to obtain multi-direction deflectmetric data of a transient field and then to reconstruct the 3-D temperature distribution by computer tomography. The problem of sampling angle for asymmetric field is analyzied in theory, and the relation between angle interval and angle frequency is presented. In this paper a space 3-D temperature distribution of asymmetric flame is measured by using pulse YAG laser as source in this method, and the accuracy of measured result is consist with that obtained by interfcrometry.