Research of photoacoustic spectroscopy effect of ethylene concentration detected by laser

  • Corresponding author: HU Bing, hubing@hust.edu.cn
  • Received Date: 2015-03-06
    Accepted Date: 2015-04-20
  • In order to solve the problem of ethylene detection of trace concentration in biomedical, petrochemical industry, CO2 laser was used to excite photoacoustic spectroscopy effect in photoacoustic cell for ethylene concentration detection. Parameters of photoacoustic cell was designed and optimized. The relationship between laser lines 10P(16), 10P(18) and ethylene absorption coefficient was investigated, and the link of ethylene concentration and photoacoustic signal was studied. Through theoretical analysis and experimental research, the results show that parameters of photoacoustic system are: center of resonant frequency of 833Hz, quality factor of 20.8, and photoacoustic cell of 2323Pacm/W. When laser power is 3.6W, photoacoustic signal and ethylene volume fraction get good linear relationship under the irradiation of two laser spectrum. Linear fit is 0.99744 and 0.99802 respectively. The minimum detectable concentration of system is 0.9nmol/L. Experimental results and theoretical analysis verify the effect of photoacoustic spectroscopy detection of trace concentrations of ethylene has good appliciation value.
  • 加载中
  • [1]

    WANG C J, SAHAY P. Breath analysis using laser spectroscopic techniques:breath biomarkers, spectral fingerprints, and detection limits[J]. Sensors, 2009, 9(10):8230-8262.
    [2]

    ARAKELIAN V G. The long way to the automatic chromatographic analysis of gases dissolved in insulating oil[J]. Electrical Insulation Magazine, 2004, 20(6):8-25.
    [3]

    ZHOU L J, WU G N, TANG P, et al. Model of semiconductor gas sensor for monitoring dissolved gases in insulation oil[J]. Automation of Electric Power Systems, 2006, 30(10):75-79 (in Chinese).
    [4]

    LI H L, ZHOU F J, TAN K X, et al. Quantitative analysis of FTIR-used intransformer on-line monitoring[J]. Automation of Electric Power Systems, 2005, 29(18):62-65 (in Chinese).
    [5]

    KERR E L, ATWOOD J G. The laser illuminated absorptivity spectrophone:a method for measurement of weak absorptivity in gases at laser wavelengths[J]. Applied Optics, 1968, 7(5):915-921.
    [6]

    LI J S, CHEN W D, YU B L, et al. Recent progress on infrared photoacoustic spectroscopy techniques[J]. Applied Spectroscopy Reviews, 2011, 46(6):460-471.
    [7]

    YUN Y X, ZHAO X X, CHEN W G,et al. Acetylene detection by laser resonant photoacoustic spectrometry[J]. Voltage Engineering, 2009, 35(9):184-190 (in Chinese).
    [8]

    LIN C, ZHU Y, WEI W, et al. Quartz-enhanced photoacoustic spectroscopy trace gas detection system based on the Fabry-Perot demodulation[J]. Spectroscopy and Spectral Analysis, 2013, 33(5):1163-1166(in Chinese).
    [9]

    TANS, LIU W F, WANG L J, et al. Mid-infrared distributed-feedback quantum cascade laser-basedphotoacoustic detection of trace methane gas[J]. Spectroscopy and Spectral Analysis, 2012, 32(5):1251-1254(in Chinese).
    [10]

    MIKLOS A, HESS P, BOZOKI Z. Application of acoustic resonators in photoacoustic trace gas analysis and metrology[J]. Review of Scientific Instruments, 2001, 72(4):1937-1955.
    [11]

    DUMITRASD D C, DUTU D C, MATEL C, et al. Laser photoacoustic spectroscopy:principles, instrumentation, and characterization[J]. Journal of Optoelectronics and Advance Materials, 2007, 9(12):3655-3701.
    [12]

    TAVAKOLI M, TAVAKOLI A, TAHERI M. Design, simulation and structural optimization of a longitudinal acoustic resonator for trace gas detection using laser photoacoustic spectroscopy[J]. Optics and Laser Technology, 2010, 42(5):828-838.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(7396) PDF downloads(219) Cited by()

Proportional views

Research of photoacoustic spectroscopy effect of ethylene concentration detected by laser

    Corresponding author: HU Bing, hubing@hust.edu.cn
  • 1. College of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074, China

Abstract: In order to solve the problem of ethylene detection of trace concentration in biomedical, petrochemical industry, CO2 laser was used to excite photoacoustic spectroscopy effect in photoacoustic cell for ethylene concentration detection. Parameters of photoacoustic cell was designed and optimized. The relationship between laser lines 10P(16), 10P(18) and ethylene absorption coefficient was investigated, and the link of ethylene concentration and photoacoustic signal was studied. Through theoretical analysis and experimental research, the results show that parameters of photoacoustic system are: center of resonant frequency of 833Hz, quality factor of 20.8, and photoacoustic cell of 2323Pacm/W. When laser power is 3.6W, photoacoustic signal and ethylene volume fraction get good linear relationship under the irradiation of two laser spectrum. Linear fit is 0.99744 and 0.99802 respectively. The minimum detectable concentration of system is 0.9nmol/L. Experimental results and theoretical analysis verify the effect of photoacoustic spectroscopy detection of trace concentrations of ethylene has good appliciation value.

Reference (12)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return