Reconstruction of temperature field around horizontal cylinder based on double-exposure holography

  • Received Date: 2014-06-26
    Accepted Date: 2014-10-31
  • Double-exposure holography is widely adopted in temperature field visualization because of the output of infinite fringes which directly present the wavefront distortion. When the wall temperature of the natural convection horizontal cylinder in 25mm diameter and 350mm length dropped from 72℃ to 22℃, the simple interferometric fringes were obtained using the double-exposure holography to study temperature field. Stripe displacements at different angels were extracted by fringe center method. Peak values and valley values of R channel of interferogram were corresponding to the centers of bright and dark fringes. Distributions of fringe orders were achieved and temperature field was inversed. The maximum of relative error of wall temperature between inversion values and thermocouple measurement values was 0.059. The results show that the data of double-exposure holography is feasible and reliable. The study is helpful for simple and fast inversion of temperature field.
  • 加载中
  • [1]

    AMBROSINI D, RASTOGI P K. Optical methods in heat transfer and fluid flow[J]. Optics and Lasers in Engineering ,2006, 44(3/4): 155-158.
    [2]

    MAUGER C, MEES L, MICHARD M, et al. Shadowgraph, schlieren and interferometry in a 2-D cavitating channel flow[J]. Experiments in Fluids, 2012, 53(6): 1895-1913.
    [3]

    LI G B, LI Q, CHEN Z M, et al. Measurement of FBG reflection spectra by white light interferometry[J]. Laser Technology, 2013, 37(1): 20-23(in Chinese).
    [4]

    SAITOH T, MARUHARA K. Bench mark solutions to natural convection heat transfer problem around a horizontal circular cylinder[J]. International Journal of Heat and Mass Transfer, 1993, 36(5): 1251-1259.
    [5]

    QI J A, WONG W O, LEUNG C W, et al. Temperature field measurement of a premixed butane/air slot laminar flame jet with Mach-Zehnder interferometry [J]. Applied Thermal Engineering, 2008, 28(14/15): 1806-1812.
    [6]

    ZHANG R, JIANG S, YAN Q Z, et al. All-fiber perimeter alarm system based on Mach-Zehnder interference[J]. Laser Technology, 2013, 37(3): 334-337(in Chinese).
    [7]

    LI X H, QIAN X F, XU Z, et al. Application of lateral shearing principle to carrier removal in grating projection[J]. Laser Technology, 2013, 37 (6): 843-848(in Chinese).
    [8]

    ZHU J R, L W, ZHOU H C. Nature convection heat transfer of horizontal cylinder with lateral shearing interferometry[J]. Journal of Chemical Industry and Engineering, 2012, 63(10): 3034-3039(in Chinese).
    [9]

    WANG D Z, HUANG Z, ZHANG L F. The development of laser technique applied in the field of fuel spray experiment[J]. Laser Technology, 1995, 19(1): 26-33(in Chinese).
    [10]

    KATZ J, SHENG J. Applications of holography in fluid mechanics and particle dynamics[J]. Annual Review of Fluid Mechanics, 2010, 42(1): 531-555.
    [11]

    HERRAEZ J V, BELDA R. A study of free convection in air around horizontal cylinder of different diameters based on holographic interferometry. Temperature field equations and heat transfer coefficients[J]. International Journal of Thermal Science, 2002, 41(3): 261-267.
    [12]

    SHARMA S, SHEORAN C. Temperature measurement of axisymmetric flame under the influence of magnetic field using lensless Fourier transform digital holography[J]. Applied Optics, 2012, 51(19): 4552-4562.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(4652) PDF downloads(660) Cited by()

Proportional views

Reconstruction of temperature field around horizontal cylinder based on double-exposure holography

  • 1. School of Materials Science and Engineering, Wuhan University of Technology, Wuhan 430070, China;
  • 2. School of Science, Hubei University of Technology, Wuhan 430068, China

Abstract: Double-exposure holography is widely adopted in temperature field visualization because of the output of infinite fringes which directly present the wavefront distortion. When the wall temperature of the natural convection horizontal cylinder in 25mm diameter and 350mm length dropped from 72℃ to 22℃, the simple interferometric fringes were obtained using the double-exposure holography to study temperature field. Stripe displacements at different angels were extracted by fringe center method. Peak values and valley values of R channel of interferogram were corresponding to the centers of bright and dark fringes. Distributions of fringe orders were achieved and temperature field was inversed. The maximum of relative error of wall temperature between inversion values and thermocouple measurement values was 0.059. The results show that the data of double-exposure holography is feasible and reliable. The study is helpful for simple and fast inversion of temperature field.

Reference (12)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return