Advanced Search

ISSN1001-3806 CN51-1125/TN Map

Volume 39 Issue 2
Dec.  2014
Article Contents
Turn off MathJax

Citation:

Real-time digital holographic microscopy based on parallel calculation

  • Received Date: 2014-06-12
    Accepted Date: 2014-07-04
  • For real-time measurement of digital holographic microscopy (DHM), a parallel algorithm was proposed. Firstly, real-time recording strategy was adopted to record hologram, intensity of object wave and intensity of reference wave according to light path of DHM. Zero-order of hologram was removed by this strategy. So, the product of spatial band-width of image sensor was efficiently utilized. Then, parallel reconstructing software was developed. The captured image was separated to four partitions and was sent to four procedures which run simultaneously. After the partitions were reconstructed by the corresponding procedure, each reconstructed result was separated to four regions. The corresponding regions were combined to four groups and were sent to four procedures for superposing and calculating phase and intensity. Finally, the whole phase and intensity map were obtained by merging four regions of phase and intensity. The experimental results reveal that the speed for image capture and hologram reconstruction is up to 18frame/s. Real-time measurement is realized with the proposed system.
  • 加载中
  • [1]

    ZHU L W, ZHOU C H, WU T F, et al. Femtosecond off-axis digital holography for monitoring dynamic surface deformation[J]. Applied Optics, 2010, 49(13):2510-2518.
    [2]

    BOUCHERIT S, BOUAMAMA L, BENCHICKH H, et al. Three-dimensional solid particle positions in a flow via multiangle off-axis digital holography[J]. Optics Letters, 2008, 33(18):2095-2097.
    [3]

    KEMPER B, CARL D, SCHNEKENBURGER J, et al. Investigation of living pancreas tumor cells by digital holographic microscopy[J]. Journal of Biomedical Optics, 2006, 11(3): 034005.
    [4]

    YU L F, MOHANTY S, ZHANG J, et al. Digital holographic microscopy for quantitative cell dynamic evaluation during laser microsurgery[J]. Optics Express, 2009, 17(14): 12031-12038.
    [5]

    ZHAO J, WANG D Y, LI Y, et al. Experimental study on the quantitative phase-contrast imaging of the biological samples by digital holographic microscopy[J]. Chinese Journal of Lasers, 2010, 37(11):2906-2911(in Chinese).
    [6]

    WENG J W, ZHONG J G, HU C Y. Digital reconstruction based on angular spectrum diffraction with the ridge of wavelet transform in holographic phase-contrast microscopy[J]. Optics Express, 2008, 16(26): 21971-21981.
    [7]

    DU Y, ZHANG Y A, QIAN X F, et al. The design of real-time digital hologram reconstruction system by mixed programming[J]. Laser Technology, 2011, 35(6):841-843(in Chinese).
    [8]

    MARQUET P, RAPPAZ B, MAGISTRETTI P, et al. Digital holographic microscopy: a noninvasive contrast imaging technique allowing quantitative visualization of living cells with subwavelength axial accuracy[J]. Optics Letters, 2005, 30(5): 468-470.
    [9]

    KEMPER B, VON B G. Digital holographic microscopy for live cell applications and technical inspection[J]. Applied Optics, 2008, 47(4): A52-A61.
    [10]

    QIU P Z, WANG H, JIN H Z, et al. Study on the simplified phase-shifting digital holographic microscopy[J]. Optik, 2010, 121(14):1251-1256.
    [11]

    MA L H, WANG H, LI Y, et al. Effect of system parameters on the reconstructed image quality in digital holographic microscopy[J]. Acta Photonica Sinica, 2011, 40(2):300-307(in Chinese).
    [12]

    MA L, WANG H, LI Y, et al. Partition calculation for zero-order and conjugate image removal in digital in-line holography[J]. Optics Express, 2012, 20(2):1805-1815.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(2950) PDF downloads(461) Cited by()

Proportional views

Real-time digital holographic microscopy based on parallel calculation

  • 1. Ningbo Yongxin Optics Co. Ltd., Ningbo 315040, China;
  • 2. Department of Optical Engineering, Zhejiang University, Hangzhou 310017, China;
  • 3. Institute of Information Optics, Zhejiang Normal University, Jinhua 321004, China

Abstract: For real-time measurement of digital holographic microscopy (DHM), a parallel algorithm was proposed. Firstly, real-time recording strategy was adopted to record hologram, intensity of object wave and intensity of reference wave according to light path of DHM. Zero-order of hologram was removed by this strategy. So, the product of spatial band-width of image sensor was efficiently utilized. Then, parallel reconstructing software was developed. The captured image was separated to four partitions and was sent to four procedures which run simultaneously. After the partitions were reconstructed by the corresponding procedure, each reconstructed result was separated to four regions. The corresponding regions were combined to four groups and were sent to four procedures for superposing and calculating phase and intensity. Finally, the whole phase and intensity map were obtained by merging four regions of phase and intensity. The experimental results reveal that the speed for image capture and hologram reconstruction is up to 18frame/s. Real-time measurement is realized with the proposed system.

Reference (12)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return