Measurement of the third harmonic energy of a large- aperture high power laser

  • Received Date: 2013-11-08
    Accepted Date: 2013-12-03
  • In order to measure energy of the third harmonic (TH) of a large aperture high power laser experiment platform, with a concave mirror sampling the beam, with a novel absorbing glass element filtering the beam, the influence of the absorbing glass element on the measurement result was experimentally tested. According to the data analysis, by using such a novel absorbing glass element, pure TH laser can be obtained and the influence of the residual fundamental and the second harmonic light is about 0.4%. The uncertainty of energy measurement of the entire TH laser energy can be controlled within 5%, which guarantees the reliability of energy measurement for the laser facility.
  • 加载中
  • [1]

    HAYNAM C A, WEGNER P J, AUERBACH J M, et al. National Ignition Facility laser performance status[J].Applied Optics,2007,46(16):3276-3303.
    [2]

    JIANG S E, DING Y K, MIAO W Y,et al. Recent progress of inertial confinement fusion experiments in China[J]. Scientia Sinica,2009,G39(11):1571-1583(in Chinese).
    [3]

    ANDRE M L.The french megajoule laser project (LMJ)[J].Fusion Engineering and Design,1999,44(1):43-49.
    [4]

    WARD H, LAFOND E, JULIEN X.Computation of thermally distorted wave-fronts in high-power lasers: comparison with LIL experiments [J]. Journal de Physique Ⅳ (Proceedings),2006,133:687-689.
    [5]

    FLEUROT N, CAVAILLER C, BOURGADE J L. The laser m'egajoule (LMJ) project dedicated to inertial confinement fusion: Development and construction status [J].Fusion Engineering and Design,2005,74(1/4):147-154.
    [6]

    PENG Z T, WEI X F, YUAN H Y, et al. Signal noise ratio of total internal reflection edge illumination for optics damage inspection[J].Infrared and Laser Engineering,2011,40(6):1111-1114(in Chinese).
    [7]

    XU L B, PENG Z T, SUN Z H, et al. Gamage online inspection technology of driver terminal optical elements[J].Infrared and Laser Engineering,2009,38(4):721-724(in Chinese).
    [8]

    ZHAO D F, WANG L, LIN Z Q, et al. Experimental study of 351nm propagation with high fluence on No.9 system of SGⅡ laser facility[J].Chinese Journal of Lasers,2011,38(7):0702001(in Chinese).
    [9]

    XIA Y W, SUN Z H, DA Z S, et al. Measurement systems of a large-aperture high power laser experiment platform[J].Acta Optica Sinica,2013,33(F06):s112003(in Chinese).
    [10]

    LEEPER R J, CHANDLER G A, COOPOER G W, et al.Target diagnostic system for the national ignition facility[J]. Review of Scientific Instruments,1997, 68(1):868-879.
    [11]

    LI X T,CEN Z F,DENG S T, et al. Ghost analysis of the terminal optical system in high power laser set[J]. Infrared and Laser Engineering, 2008, 37(5):809-812(in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3000) PDF downloads(266) Cited by()

Proportional views

Measurement of the third harmonic energy of a large- aperture high power laser

  • 1. Research center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900, China

Abstract: In order to measure energy of the third harmonic (TH) of a large aperture high power laser experiment platform, with a concave mirror sampling the beam, with a novel absorbing glass element filtering the beam, the influence of the absorbing glass element on the measurement result was experimentally tested. According to the data analysis, by using such a novel absorbing glass element, pure TH laser can be obtained and the influence of the residual fundamental and the second harmonic light is about 0.4%. The uncertainty of energy measurement of the entire TH laser energy can be controlled within 5%, which guarantees the reliability of energy measurement for the laser facility.