Advanced Search

ISSN1001-3806 CN51-1125/TN Map

Volume 37 Issue 3
Mar.  2013
Article Contents
Turn off MathJax

Citation:

Study on measurement of sight-line alteration of high precision sighting telescopes

  • Received Date: 2012-07-02
    Accepted Date: 2012-09-26
  • In order to solve the difficulty of the performance testing of high precision sighting telescope,i.e.,testing its sight-line alteration under various environmental test conditions,a test system was designed based on CCD image test technology.Firstly,the position difference of the anchor was measured through measuring the positions of the connection seat anchor points before and after test.Secondly,according to this data,the fixing base of the precision sighting telescope was adjusted to make the connection seat anchor recover to the initial position.Finally,the alteration of the sight-line was measured and figured out.Based on an optical collimator,the focal length of the CCD optical system was measured and the system accuracy was analyzed.Inpractical engineering applications,the measurement error was less than 2.16" and measuring range was larger than 4320",which met the project requirements.The results show that the test method is accurate and reliable and detection precision is high.This test system offers a method for testing the sight-line alteration of high precision sighting telescopes.
  • 加载中
  • [1]

    ZHU Y Ch.Introduction to environmental engineering products[M].Beijing:Aviation Industry Press,2003:65-69(in Chinese).
    [2]

    WANG Zh M.Targeting instrument principle and design[M].Beijing:Beijing Institute of Technology Press,1996:8-10(in Chinese).
    [3]

    WANG Q Y.CCD application technology[M].Tianjin:Tianjin University Press,2001:173(in Chinese).
    [4]

    QU P,LIN X R.An automatic focus system based on the image processing[J].Application of Electronic Technology,2002,28(10):33-35(in Chinese).
    [5]

    YANG R N,AN Zh Y,SHI L X,et al.Research on modem test system for graduation inclining andimage inclining in optical sighting telescope[J].Chinese Journal of Scientific Instrument,2008,29(8):1731-1734(in Chinese).
    [6]

    WANG W,ZAO H,TAO W.Research and improvement of linear measurement method for automatic aiming system[J].Process Automation Instrumentation,2006,27(5):33-35(in Chinese).
    [7]

    ZHOU Zh L,WANG B.The method research for pinpoint laser spot location in the imaging laser detecting system[J].Leaser Technology,2008,32(3):248-251(in Chinese).
    [8]

    LÜ P,HAN G H.Application of dual wedges in optical axis alignment for laser rangefinders[J].Laser Technology,2012,36(2):151-153(in Chinese).
    [9]

    SHEN Y Ch,HU B,PANG D,et al.GJB 5815-2006The approval test methods of optical sight for small arms[S].Beijing:General Armament Department Military Standardization Research Center,2006:7-11(in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3440) PDF downloads(641) Cited by()

Proportional views

Study on measurement of sight-line alteration of high precision sighting telescopes

  • 1. No.208 Research Institute of China Ordnance Industries, Beijing 102202, China

Abstract: In order to solve the difficulty of the performance testing of high precision sighting telescope,i.e.,testing its sight-line alteration under various environmental test conditions,a test system was designed based on CCD image test technology.Firstly,the position difference of the anchor was measured through measuring the positions of the connection seat anchor points before and after test.Secondly,according to this data,the fixing base of the precision sighting telescope was adjusted to make the connection seat anchor recover to the initial position.Finally,the alteration of the sight-line was measured and figured out.Based on an optical collimator,the focal length of the CCD optical system was measured and the system accuracy was analyzed.Inpractical engineering applications,the measurement error was less than 2.16" and measuring range was larger than 4320",which met the project requirements.The results show that the test method is accurate and reliable and detection precision is high.This test system offers a method for testing the sight-line alteration of high precision sighting telescopes.

Reference (9)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return