Advanced Search

ISSN1001-3806 CN51-1125/TN Map

Volume 37 Issue 3
Mar.  2013
Article Contents
Turn off MathJax

Citation:

A large step method of optical microscanning

  • Received Date: 2012-07-02
    Accepted Date: 2012-09-04
  • Rotating inclined optical parallel plate is a kind of optical microscanning method.In order to overcome rigorous requirement for size of optical parallel plate,a large step method of optical microscanning was proposed.Firstly,its effect on the image aliasing and modulation transfer function(MTF) of the detector was theoretically analyzed.Then,it was experimentally confirmed by quantitative comparison of super-resolution image quality.The results indicate that not only machining difficulty is reduced,but also the aliasing is restrained and the MTF is sustained by using the large step microscanning.
  • 加载中
  • [1]

    FORNTIN J,CHEVRETTE P,PLANTE R.Evaluation of the microscanning process[J].Proceedings of SPIE,1994,2269:271-279.
    [2]

    WILTSE J M,MILLER J L.Imagery improvements in staring infrared imagers by employing subpixel microscan[J].Optics Engineering,2005,44(5):056401.
    [3]

    FORNTIN J,CHEVRETTE P.Realization of a fast microscanning device for infrared focal plane arrays[J].SPIE,1996,2742:185-196.
    [4]

    SUI X B,BAI L F,CHEN Q,et al.Influencing factors of microscanning performance based on fat optical component[J].Chinese Optics Letters,2011,9(5):052302.
    [5]

    KRAPELS K,DRIGGERS R,VOLLMERHAUSEN R,et al.A performance comparison of rectangular(4-point) and diagonal(2-point) dither[J].Proceedings of SPIE,2000,4030:151-169.
    [6]

    QU H M,CHEN Q.Comparison of microscanning schemes in infrared focal plane array imaging[J].Laser & Infrared,2006,36(3):161-164(in Chinese).
    [7]

    WATSON E A,MUSE R A,BLOMMEL F P.Aliasing and blurring in microscanned imagery[J].Proceedings of SPIE,1992,1689:242-250.
    [8]

    WANG X,ZHANG J,FENG Z,et al.Analysis of improvement amount of typical microscanning modes to IR imagery quality[J].Infrared Physics & Technology,2005,46(5):412-417.
    [9]

    FRIEDENBERG A.Microscan in infrared staring systems[J].Optics Engineering,1997,36(6):1745-1749.
    [10]

    CHEN H.Research of image quality assessment and restoration system[D].Shanghai:Shanghai Jiaotong University,2010:22-23(in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3303) PDF downloads(566) Cited by()

Proportional views

A large step method of optical microscanning

  • 1. School of Instrumention Science and Opto-electronics Engineering, Beihang University, Beijing 100191, China;
  • 2. Yunnan Lincang Xinyuan Germanium Industrial Co.Ltd., Kunming 650031, China

Abstract: Rotating inclined optical parallel plate is a kind of optical microscanning method.In order to overcome rigorous requirement for size of optical parallel plate,a large step method of optical microscanning was proposed.Firstly,its effect on the image aliasing and modulation transfer function(MTF) of the detector was theoretically analyzed.Then,it was experimentally confirmed by quantitative comparison of super-resolution image quality.The results indicate that not only machining difficulty is reduced,but also the aliasing is restrained and the MTF is sustained by using the large step microscanning.

Reference (10)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return