Study on analogical differential-phase low homological optical reflecting technique
-
1.
College of Physics and Telecommunication Engineering, Shaanxi University of Technology, Hanzhong 723003, China
-
Received Date:
2011-12-23
Accepted Date:
2012-03-27
-
Abstract
In order to obtain higher measurement resolution,an analogical differential-phase low homological optical reflecting system was developed with a differential amplifier combined with a high magnification microscope objective lens based on a low homological light source and a Michelson interferometer.High signal-to-noise ratio and high sensitivity can be obtained by means of the balanced detecting structure.The high time-frequency width product can be acquired by using the differential amplifier with frequency width of 100MHz.Thus a higher sensitivity can be achieved for measuring the surface morphology and moving rate.The result indicates that the local measurement by use of a super luminiferous diode(SLD) with narrow frequency width and a microscope objective with large number aperture has the same effect on local location.
-
-
References
[1]
|
WANG L,DING Zh H,HUANG L N,et al.Numerical analysis on oxygen saturation measurement in human retinal blood vessel by dualwavelength optical low-coherence interferometry[J].Acta Photonica Sinica,2007,36(6):209-212(in Chinese). |
[2]
|
LI Zh Y,YU Y G,YE H Y.Measuring tiny displacement based on moderate optical feedback self-mixing interferometry[J].Laser Technology,2008,32(5):499-501(in Chinese). |
[3]
|
DAVéD P,MILNER T E.Optical low-coherence reflectometer for differential phase measurement[J].Optics Letters,2000,25(4): 227-229. |
[4]
|
SIAVASH Y,JOSEOH A I.Self-referenced Doppler optical coherence tomography[J].Optics Letters,2002,27(23):2085-2087. |
[5]
|
ADLER D C,HUBER R,FUJIMOTO J G.Phase-sensitive optical coherence tomography at up to 370,000 lines per second using buffered Fourier domain mode-locked lasers[J].Optics Letters,2007, 32(6):626-628. |
[6]
|
LIU J J.Analysis of few problems in the experiment of measuring the wave length with Michelson interferometer[J].Experiment Science& Technology,2010,8(1):31-32(in Chinese). |
[7]
|
LIU Ch L,WANG H L,FANG X Y,et al.Research on the SPR sensor based on Michelson interferometer[J].Chinese Journal of Sensors and Actuators,2010,23(5):635-638(in Chinese). |
[8]
|
WANG F,QI X D.Grating heterodyne interferometer of high accuracy controlling photoelectric grating ruling engine[J].Laser Technology,2008,32(5):474-476(in Chinese). |
[9]
|
LI Sh M,MEI H P,QIAN X M,et al.Demodulating atmospheric turbulence random phase difference based on Hilbert transform[J]. Acta Photonica Sinica,2011,31(7):34-38(in Chinese). |
[10]
|
BIAN H L,CHEN G,LI L,et al.Measurement algorithm of nonstationary signal based on time and frequency optimization using wavelet packet transform[J].Chinese Journal of Scientific Instrument, 2009,30(3):498-502(in Chinese). |
-
-
Proportional views
-