Advanced Search

ISSN1001-3806 CN51-1125/TN Map

Volume 36 Issue 2
Jan.  2012
Article Contents
Turn off MathJax

Citation:

Correction model mixed with least-square and grid method for dual galvanometric scanning

  • Corresponding author: MENG Wen, mengwen_mw@126.com
  • Received Date: 2011-06-10
    Accepted Date: 2011-06-23
  • In order to decrease nonlinear distortion error in the state of wide-angle scanning of a two-dimension galvanometer scanning system,aiming at the defects of various errors in the system itself which cannot be overcame absolutely by single theoretical correction model,the correction model based on mapping connection between coordinates and angles was put forward.The error compensation surface of coordinate points was established by means of the least square surface fitting method,and the correction precision was effectively improved,the error of test points could be limited around 15μm.The scanning speed can be obviously increased by the grid correction table plugged by piecewise linear interpolation in the scanning plane,and the scanning speed can get to 25m/s or so.Simulation results show that the model is effective for real-time dynamic adjusting of nonlinear scanning.
  • 加载中
  • [1]

    JABLONOWSKI D P,RAAMOT J.Beam deflection at high accuracy and precision[J].SPIE,1976,84:69-76.
    [2]

    ZHU L Q.Error analysis and correcting method of the two vibrational mirrors scanning system[J].Applied Laser,2001,21(5):325-327(in Chinese).
    [3]

    WAN Z,DU W X.Calibration of graphic distortion and compensation of exposure for dual galvanometer scanning[J].Optics and Precision Engineering,2000,8(2):115-118(in Chinese).
    [4]

    JIN H,JIA J J,SHU R.Analaysis of scanning characteristics of a twodimensional scanning lidar[J].Infrared,2010,31(6):10-14(in Chinese).
    [5]

    TANG W.Characteristics of a double galvanometer deflection system with a distortion Lens[J].Acta Optica Sinica,1987,7(3):261-268(in Chinese).
    [6]

    YU X S.Distortion correction for dual galvanometer scanning[J].Laser & Infrared,1998,28(1):45-47(in Chinese).
    [7]

    XU Y P,TAO X H.Effect of scanner's structure on accuracy[J].Applied Laser,1998,18(4):169-170(in Chinese).
    [8]

    WEN S F,SHI Y S,XIE J,et al.Study on key technology for 3-D galvanometric scanners[J].Laser Technology,2009,33(4):377-380(in Chinese)
    [9]

    LIU C M.Study on working principle and graphic distortion of galvanometer scanning in laser large screen displayer[J].Chinese Journal of Lasers,2003,30(3):263-266(in Chinese).
    [10]

    EHRMANN J S.Inertia-optimized mirror geometry and compound imaging optics forprecision laser scanning[J].SPIE,1998,3482:560-571.
    [11]

    SUN H L,LIN S Z.Research on errors reasons in dual galvanometric laser scanning manufacturing[J].Laser & Infrared,2005,35(3):161-163(in Chinese).
    [12]

    JIA H P,SHI Y S,XIE J.Error analysis of laser galvanometer scan system and its geometrical correction arithmetic[J].Opto-Electronic Engineering,2007,34(8):37-40(in Chinese).
    [13]

    ZHAO Y,LU B H.Pillow shaped distortion correction algorithm of galvanometric scanning system[J].Chinese Journal of Lasers,2003,30(3):216-218(in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3837) PDF downloads(518) Cited by()

Proportional views

Correction model mixed with least-square and grid method for dual galvanometric scanning

    Corresponding author: MENG Wen, mengwen_mw@126.com
  • 1. Telecomunication Engineering Institute, Air Force Engineering University, Xi'an 710077, China

Abstract: In order to decrease nonlinear distortion error in the state of wide-angle scanning of a two-dimension galvanometer scanning system,aiming at the defects of various errors in the system itself which cannot be overcame absolutely by single theoretical correction model,the correction model based on mapping connection between coordinates and angles was put forward.The error compensation surface of coordinate points was established by means of the least square surface fitting method,and the correction precision was effectively improved,the error of test points could be limited around 15μm.The scanning speed can be obviously increased by the grid correction table plugged by piecewise linear interpolation in the scanning plane,and the scanning speed can get to 25m/s or so.Simulation results show that the model is effective for real-time dynamic adjusting of nonlinear scanning.

Reference (13)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return