Advanced Search

ISSN1001-3806 CN51-1125/TN Map

Volume 36 Issue 1
Dec.  2011
Article Contents
Turn off MathJax

Citation:

Study on LiNbO3 electro-optical switches with low driving voltage

  • Received Date: 2011-06-28
    Accepted Date: 2011-07-06
  • In order to reduce the driving voltage of an electro-optical switch,a LiNbO3 crystal was placed in a Fabry-Perot cavity and the transmissive characteristics of this Fabry-Perot electro-optical switch was investigated experimentally.The results showed that the driving voltage of the Fabry-Perot electro-optical switch was ~580V,which was much lower than the half-wave voltage of an electro-optical switch used as orthogonal polarizer,~2.1kV.Moreover,the rising time of the Fabry-Perot electro-optical switch,128μs,was shorter than that of a switch used as orthogonal polarizer,284μs.Theoretical analysis of transmitted characteristic dependence on driving voltage was performed,and the results were in accordance with the experimental results.
  • 加载中
  • [1]

    ZHOU B K,GAO Y Zh,CHEN T R,et al.Laser principle[M].Beijing:National Defense Industry Press,2000:221-223 (in Chinese).
    [2]

    LI Zh J,HU W H,LI X F,et al.A compact high-efficiency air-cooled Q-switched Nd:Ce:YAG laser[J].Journal of Optoelectronics·Laser,2001,12(4):382-384(in Chinese).
    [3]

    HUANG Ch H,ZHANG G,WEI Y,et al.1.3414μm Nd:YAlO3 Qswitched pulse laser[J].Laser Journal,2006,27 (2):26-27 (in Chinese).
    [4]

    NING G B,LIANG Zh,ZHAO Zh M,et al.High repetition rate electrooptical Q-switching of CW Nd:YAG laser[J].Acta Optica Sinica,2000,20 (11):1481-1485 (in Chinese).
    [5]

    WEN W Q,FU R L,SUN J T,et al.Active Q-switch Nd:YAG lasers end-pumped by QCW-LD[J].Journal of Optoelectronics · Laser,2002,13(10):994-996(in Chinese).
    [6]

    FENG Y W,DAI Sh T,ZHU X L.lkHz electro-optic Q-switched Nd:YAG laser with complete compensation of thermally induced depolarization loss[J].Chinese Journal of Lasers,2007,34(9):1190-1193 (in Chinese).
    [7]

    CHEN R,ZHAI G,JIN F,et al.Study on pulsed electro-optic Qswitched Nd:YAG laser at 1319nm[J].Laser Technology,2010,34(5):603-606(in Chinese).
    [8]

    MACHINTOSH I W.Repetitive Q-switching of a continuously pumped Nd:YAG laser using a Fabry-Perot interferometer[J].Physics Letters,1969,A28(7):497-498.
    [9]

    MACHINTOSH I W.Double etalon Q-switching of a continuously pumped Nd:YAG laser[J].Applied Optics,1969,8(10):1991-1998.
    [10]

    ZAYHOWSKI J J,DILL Ⅲ C.Diode-pumped microchip lasers electro-optically Q-switched at high pulse repetition rates[J].Optics Letters,1992,17(17):1201-1203.
    [11]

    ZAYHOWSKI J J,DILL Ⅲ C.Coupled-cavity electro-optically Qswitched Nd:YVO4 microchip lasers[J].Optics Letters,1995,20(7):716-718.
    [12]

    WANG Y X,HUANG L,GONG M L,et al.Low voltage driving coupled-cavity electro-optically Q-switched microchip lasers[J].Chinese Journal of Lasers,2008,35(s1):9-12(in Chinese).
    [13]

    ZHAO K H,ZHONG X H.Optics[M].Beijing:Peking University Press,1982:338-340(in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3648) PDF downloads(513) Cited by()

Proportional views

Study on LiNbO3 electro-optical switches with low driving voltage

  • 1. Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China

Abstract: In order to reduce the driving voltage of an electro-optical switch,a LiNbO3 crystal was placed in a Fabry-Perot cavity and the transmissive characteristics of this Fabry-Perot electro-optical switch was investigated experimentally.The results showed that the driving voltage of the Fabry-Perot electro-optical switch was ~580V,which was much lower than the half-wave voltage of an electro-optical switch used as orthogonal polarizer,~2.1kV.Moreover,the rising time of the Fabry-Perot electro-optical switch,128μs,was shorter than that of a switch used as orthogonal polarizer,284μs.Theoretical analysis of transmitted characteristic dependence on driving voltage was performed,and the results were in accordance with the experimental results.

Reference (13)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return