Advanced Search

ISSN1001-3806 CN51-1125/TN Map

Volume 35 Issue 5
May  2013
Article Contents
Turn off MathJax

Citation:

Measurement of complete Stokes parameters of 2-D polarized light

  • Received Date: 2010-11-16
    Accepted Date: 2010-12-21
  • In order to measure the complete Stokes parameters of the target accurately, the effect of systematic disturbance on the measurement accuracy was analyzed based on the numerical simulation method of 2-norm condition number of measurement matrices and verified in experiments. Simulation study shows that the measuring system can run optimally and effectively when the angles of the fast axis of the /4 wave-plate are appropriate combination angles (i.e., 13, 50, 128, 164).
  • 加载中
  • [1]

    QIAO Y L,YANG Sh Zh,LUO R Zh,et al.Research on polarized spectral monitoring for remote sensing of earth[J].High Technology Letters,2001,11(7):36-39(in Chinese).
    [2]

    DESCHAMPS P Y,HERMAN M,PODAIRE A,et al.The POLDER instrument:mission objectives[J].SPIE,1992,1746:72-91.
    [3]

    SUN X B,HONG J,QIAO Y L,A method of image feature extraction based angle of polarization[J].Remote Sensing Technology Application,2005,20(2):256-260(in Chinese).
    [4]

    CAO H,SONG L K,PENG H D,et al.The study of the relationship between polarized light's incident azimuth and intermediary reflectance[J].Laser Technology,2005,29(1):104-105(in Chinese).
    [5]

    TRAVIS L D.Remote sensing of aerosols with the earth observing scanning polarimeter[J].SPIE,1992,1747:154-164.
    [6]

    CHEN L G,HONG J,QIAO Y L,et al.Accuracy analysis of polarimetric measurement based on double Wollaston prisms[J].Laser Technology,2008,32(5):468-470 (in Chinese).
    [7]

    DEUZE J L,BREON F M,DESCHAMPS P Y,et al.Polarization measurements with the airborne version of the POLDER instrument[J].SPIE,1992,1747:178-187.
    [8]

    DEUZE J L,GOLOUB P,HERMAN M,et al.Aerosol retrieval using the POLDER instrument preliminary results[J].SPIE,1997,3121:347-355.
    [9]

    SHAO W D,WANG P G,ZHENG Q B,et al.Polarimetric calibration of airborne remote sensing polarimeter[J].Journal of Infrared and Millimeter Waves,2003,22(2):137-140 (in Chinese).
    [10]

    CHEN L G,HONG J,QIAO Y L,et al.Accuracy analysis on a sort of polarized measurement in remote sensing[J].Spectroscopy and Spectral Analysis,2008,28(10):2384-2387(in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3647) PDF downloads(792) Cited by()

Proportional views

Measurement of complete Stokes parameters of 2-D polarized light

  • 1. Department of Physics and Electronics Science, Institute of Theoretical Physics, Binzhou University, Binzhou 256603, China;
  • 2. Binzhou University Automation Department, Binzhou 256603, China;
  • 3. Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China

Abstract: In order to measure the complete Stokes parameters of the target accurately, the effect of systematic disturbance on the measurement accuracy was analyzed based on the numerical simulation method of 2-norm condition number of measurement matrices and verified in experiments. Simulation study shows that the measuring system can run optimally and effectively when the angles of the fast axis of the /4 wave-plate are appropriate combination angles (i.e., 13, 50, 128, 164).

Reference (10)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return